Application Note #480

2

www.lutron.com

Glossary

Auto-On –

  A setting which allows the user to adjust the automatic functionality of the sensor. This will change how the 

dimmer responds upon initial occupancy of the room. 

Auto-On: ALD –

  Setting where the dimmer turns on upon initial occupancy to the room only if there is NOT enough 

ambient light. The sensor will learn your preferred light level over time, through your interactions with the 

Tap button, and eventually will only turn the lights on, when there is not enough light in the room, and 

motion is detected. This setting is known as “Ambient Light Detect” mode. 

Auto-On: Disabled –

  The dimmer will only turn on when the Tap button is pressed, but will still turn off automatically, when 

you vacate the room. This setting is also known as “Vacancy” mode. 

Auto-On: Enabled –

  This is the default setting for your occupancy sensor. The sensor automatically turns on when you 

enter the room, and turns off when you vacate the room. This settiing is also known as “Occupancy” 

mode.

Auto-On: OWO –

  The sensor automatically turns on when you enter the room, and turns off when you vacate the room. If 

you manually turn the lights off, and remain in the room, this mode will allow the lights to remain off as 

long as you have not vacated the room. This setting is known as “Off-While-Occupied” mode. 

Default Setting –

 Original preset programming options that the dimmer is programmed to upon initial use.

Factory Default –

  Original preset programming options set up as a starting point for users that wish to customize settings; 

also known as default setting.

FASS

T

 –

  Tab at bottom of sensor dimmer, required to be pulled out for light bulb(s) replacement and entering all 

programming modes; also known as Air Gap.

Fast Blink –

  Indication of entering Programming Options, Indicator Lights (ILs) blink quickly at a rate of 8 flashes per 

second.

High-End Trim –

 Ability to change the highest achievable light level to which the dimmer can be adjusted.

Low-End Trim –

 Ability to change the lowest achievable light level to which the dimmer can be adjusted.

Load –

 The light bulb(s) that the dimmer is controlling.

Locked Preset –

 A programmable light level setting to which the dimmer will illuminate after a single Tap button press.

Normal Operation –

 Standard use of sensor dimmer (ON / OFF, Raise / Lower); Indicator Lights will not be blinking.

Occupied Level –

  A programmable setting that determines the light level your dimmer will turn on to, once occupancy has 

been detected.

Occupied Level: 100% –

  Your dimmer will turn all lights on to 100% of the dimmable light level when this is selected. This 

is the default mode for the dimmer.

Occupied Level: 50% –

 Your dimmer will turn all lights on to their half of their dimmable light level when this is selected. 

Occupied Level: Preset –

  Your dimmer will turn all lights on to the last light level that has been selected by the user (1% - 

100%). If you also lock your preset in the advanced programming options, your dimmer will turn 

ON to your Locked Preset light level.

Sensitivity –

 A programmable setting to adjust the level of sensitivity your sensor will have to detect motion. 

Slow Blink –

 Indication of entering programming modes, Indicator Lights (ILs) blink slowly at a rate of 4 flashes per second.

Timeout –

 A programmable setting that determines how long the lights will remain on when motion has not been detected.

Unlocked Preset -

  A light level setting that allows the dimmer to turn ON to the last dimmed setting after a single Tap 

button press.

Содержание C-L

Страница 1: ...ay be temporarily disconnected at the light fixture by pulling the FASST OUT on the dimmer For any procedure other than routine bulb replacement power MUST be disconnected at the main electrical panel...

Страница 2: ...out for light bulb s replacement and entering all programming modes also known as Air Gap Fast Blink Indication of entering Programming Options Indicator Lights ILs blink quickly at a rate of 8 flashe...

Страница 3: ...ionality of the sensor can be adjusted to control how the lights respond upon initial occupancy There are four available Auto On settings Enabled Disabled Ambient Light Detect ALD Mode and Off While O...

Страница 4: ...eset light level in Advanced Programming Mode the lights will come on to your locked preset level instead of the last level selected What do I want To fully utilize the dimming capabilities Preset mod...

Страница 5: ...of this document Programming can be found on pages 6 8 Sensor Dimmer Coverage Area Horizontal Beam Diagram 5 ft 1 5 m 5 ft 1 5 m 0 10 ft 3 m 10 ft 3 m 15 ft 4 5 m 15 ft 4 5 m 20 ft 6 m 20 ft 6 m 25 ft...

Страница 6: ...only LED 2 Sensitivity LED 1 Timeout 2 Press the Tap button one time and the feature will be selected for modification 3 Go to the appropriate section on pages 6 8 to continue its programming Selecti...

Страница 7: ...ed auto on setting 2 Press the Tap button one time to select the auto on setting and return to the main sensor menu Note The default setting is Auto On Enabled To exit Programming Mode press and hold...

Страница 8: ...amming Option 1 While in Advanced Programming Mode APM as shown below Press the Raise Lower button to select the desired Programming Option The slow blinking Indicator Light IL will indicate which Opt...

Страница 9: ...to the light level that it was adjusted to the previous time that the light was ON Note Default Setting is Unlocked Preset Directions Selecting Locked Preset 1 While in Advanced Programming Mode APM P...

Страница 10: ...that it was last set to while in Normal Operation the Unlocked Preset must be activated While in Programming Option 1 Preset Light Level Press the Lower button until the bottom Indicator Light is quic...

Страница 11: ...to the current setting and begin to blink rapidly indicating that the Programming Option has been entered 2 Upon entering the Manual Fade ON Time programming option by Pressing the Tap button and obse...

Страница 12: ...The IL will then switch to the current setting and begin to blink rapidly indicating that the Programming Option has been entered 2 Upon entering the Manual Fade OFF Time programming option by Pressin...

Страница 13: ...Option has been entered 2 Upon entering the Delayed Fade to OFF programming option by Pressing the Tap button and observing the IL changing to a fast blink Press the Raise Lower buttons to select the...

Страница 14: ...L will then switch to the current setting and begin blinking rapidly or turn OFF indicating that the programming option has been entered 2 Upon entering the Enable Disable Indicator Lights programming...

Страница 15: ...sing the Tap and observing the IL changing to a fast blink Press the Raise Lower buttons to select the desired Low End Trim level Note While setting the Low End Trim it is advised that the programmer...

Страница 16: ...o a fast blink Press the Raise Lower buttons to select the desired High End Trim level Note While setting the High End Trim it is advised that the programmer observes the actual light load and not the...

Страница 17: ...ress and hold the Tap button and the Lower button until an Indicator Light IL blinks The Load will turn OFF and then turn ON to Low End 2 Adjust light output using Raise Lower button until stable and...

Страница 18: ...justable 10 seconds To Restore Factory Defaults 1 Pull the FASST into the OFF Position OUT and Wait 5 seconds 2 Press and Hold the Tap button While continuing to hold the Tap button Push the FASST to...

Страница 19: ...njury or death Turn OFF power at circuit breaker before installing the unit Continued on next page Neutral Live Different Color Screw Black No connection Brass Sensor Dimmer 3 Way Mechanical Switch Bl...

Страница 20: ...anical switch is being used IL4 if a companion dimmer is being used 3 Single Tap to Save setting Note Rewiring of existing switch is required consult your instruction sheet for installation procedures...

Страница 21: ...e Lights may flash The Low End Trim setting may have to be adjusted Adjust the Low End Trim from the APM menu Note in this scenario the Low End Trim cannot be adjusted from the shortcut menu Refer to...

Страница 22: ...turn on in the 15 second grace period following timeout If timeout is 1 minute wait 1 minute 30 seconds to enter room again to verify lights don t turn back on Sensor Mode may be set to something othe...

Страница 23: ...5 2910 Central South America 1 610 282 6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom TEL 44 0 20 7702 0657 FAX 44 0 20 7480 6899 FREEPHONE UK...

Отзывы: