background image

Lutron Electronics Co., Inc.

7200 Suter Road

Coopersburg, PA 18036-1299 U.S.A.

P/N 048480  Rev. A   01/2013

23

Lutron Contact Numbers

Lutron, Maestro and C•L are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. 

WORLD HEADQUARTERS 

USA
Lutron Electronics Co., Inc. 

7200 Suter Road 

Coopersburg, PA 18036-1299

 

TEL: +1.610.282.3800 

FAX: +1.610.282.1243 

Toll-Free: 1.888.LUTRON1 

Technical Support: 1.800.523.9466
[email protected]

North & South America  

Technical Hotlines
USA, Canada, Caribbean: 

1.800.523.9466

 

Mexico:

 

+1.888.235.2910

 

Central/South America:

 

+1.610.282.6701

EUROPEAN HEADQUARTERS 

United Kingdom
Lutron EA Ltd. 

6 Sovereign Close 

London, E1W 3JF United Kingdom

 

TEL: +44.(0)20.7702.0657 

FAX: +44.(0)20.7480.6899 

FREEPHONE (UK): 0800.282.107 

Technical Support: +44.

(0)20.7680.4481
[email protected]

ASIAN HEADQUARTERS 

Singapore
Lutron GL Ltd. 

15 Hoe Chiang Road 

#07-03, Tower 15 

Singapore 089316

 

TEL: +65.6220.4666 
FAX: +65.6220.4333 

Technical Support: 800.120.4491

[email protected]

Asia Technical Hotlines

Northern China: 10.800.712.1536 

Southern China: 10.800.120.1536 

Hong Kong: 800.901.849 

Indonesia: 001.803.011.3994 

Japan: +81.3.5575.8411 

Macau: 0800.401 

Taiwan: 00.801.137.737 

Thailand: 001.800.120.665853 

Other Countries: +65.6220.4666

Application Note #480

Содержание C-L

Страница 1: ...ay be temporarily disconnected at the light fixture by pulling the FASST OUT on the dimmer For any procedure other than routine bulb replacement power MUST be disconnected at the main electrical panel...

Страница 2: ...out for light bulb s replacement and entering all programming modes also known as Air Gap Fast Blink Indication of entering Programming Options Indicator Lights ILs blink quickly at a rate of 8 flashe...

Страница 3: ...ionality of the sensor can be adjusted to control how the lights respond upon initial occupancy There are four available Auto On settings Enabled Disabled Ambient Light Detect ALD Mode and Off While O...

Страница 4: ...eset light level in Advanced Programming Mode the lights will come on to your locked preset level instead of the last level selected What do I want To fully utilize the dimming capabilities Preset mod...

Страница 5: ...of this document Programming can be found on pages 6 8 Sensor Dimmer Coverage Area Horizontal Beam Diagram 5 ft 1 5 m 5 ft 1 5 m 0 10 ft 3 m 10 ft 3 m 15 ft 4 5 m 15 ft 4 5 m 20 ft 6 m 20 ft 6 m 25 ft...

Страница 6: ...only LED 2 Sensitivity LED 1 Timeout 2 Press the Tap button one time and the feature will be selected for modification 3 Go to the appropriate section on pages 6 8 to continue its programming Selecti...

Страница 7: ...ed auto on setting 2 Press the Tap button one time to select the auto on setting and return to the main sensor menu Note The default setting is Auto On Enabled To exit Programming Mode press and hold...

Страница 8: ...amming Option 1 While in Advanced Programming Mode APM as shown below Press the Raise Lower button to select the desired Programming Option The slow blinking Indicator Light IL will indicate which Opt...

Страница 9: ...to the light level that it was adjusted to the previous time that the light was ON Note Default Setting is Unlocked Preset Directions Selecting Locked Preset 1 While in Advanced Programming Mode APM P...

Страница 10: ...that it was last set to while in Normal Operation the Unlocked Preset must be activated While in Programming Option 1 Preset Light Level Press the Lower button until the bottom Indicator Light is quic...

Страница 11: ...to the current setting and begin to blink rapidly indicating that the Programming Option has been entered 2 Upon entering the Manual Fade ON Time programming option by Pressing the Tap button and obse...

Страница 12: ...The IL will then switch to the current setting and begin to blink rapidly indicating that the Programming Option has been entered 2 Upon entering the Manual Fade OFF Time programming option by Pressin...

Страница 13: ...Option has been entered 2 Upon entering the Delayed Fade to OFF programming option by Pressing the Tap button and observing the IL changing to a fast blink Press the Raise Lower buttons to select the...

Страница 14: ...L will then switch to the current setting and begin blinking rapidly or turn OFF indicating that the programming option has been entered 2 Upon entering the Enable Disable Indicator Lights programming...

Страница 15: ...sing the Tap and observing the IL changing to a fast blink Press the Raise Lower buttons to select the desired Low End Trim level Note While setting the Low End Trim it is advised that the programmer...

Страница 16: ...o a fast blink Press the Raise Lower buttons to select the desired High End Trim level Note While setting the High End Trim it is advised that the programmer observes the actual light load and not the...

Страница 17: ...ress and hold the Tap button and the Lower button until an Indicator Light IL blinks The Load will turn OFF and then turn ON to Low End 2 Adjust light output using Raise Lower button until stable and...

Страница 18: ...justable 10 seconds To Restore Factory Defaults 1 Pull the FASST into the OFF Position OUT and Wait 5 seconds 2 Press and Hold the Tap button While continuing to hold the Tap button Push the FASST to...

Страница 19: ...njury or death Turn OFF power at circuit breaker before installing the unit Continued on next page Neutral Live Different Color Screw Black No connection Brass Sensor Dimmer 3 Way Mechanical Switch Bl...

Страница 20: ...anical switch is being used IL4 if a companion dimmer is being used 3 Single Tap to Save setting Note Rewiring of existing switch is required consult your instruction sheet for installation procedures...

Страница 21: ...e Lights may flash The Low End Trim setting may have to be adjusted Adjust the Low End Trim from the APM menu Note in this scenario the Low End Trim cannot be adjusted from the shortcut menu Refer to...

Страница 22: ...turn on in the 15 second grace period following timeout If timeout is 1 minute wait 1 minute 30 seconds to enter room again to verify lights don t turn back on Sensor Mode may be set to something othe...

Страница 23: ...5 2910 Central South America 1 610 282 6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom TEL 44 0 20 7702 0657 FAX 44 0 20 7480 6899 FREEPHONE UK...

Отзывы: