255-700-239
A-17
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
Appendix A SNMP Trap Messages
Viewing Trap Log Information
cirEmAtm-
SpvcVccTear-
DownNotify
Connec-
tion Event,
60
Response
cirEmAtmSpvcVccIfA,
cirEmAtmSpvcVccIfB,
cirEmAtmSpvcVc-
cVpiB, cirEmAtm-
SpvcVccVciB
An SPVC connection
between CE and ATM end-
points has been deleted.
cirEmCir-
EmPvcReqFailNo-
tify
Connec-
tion Event,
8
Response
cirEmCirEmPvcIfA, cir-
EmCirEmPvcIfB, pvc-
FailureReasonCode
The PVC connection request
between two circuit emula-
tion interfaces has failed.
cirEmCirEmPvc-
SetupNotify
Connec-
tion Event,
17
Response
cirEmCirEmPvcIfA, cir-
EmCirEmPvcIfB
The PVC connection
between two circuit-emula-
tion interfaces has been suc-
cessfully established.
cirEmCirEmPvc-
TearDownNotify
Connec-
tion Event,
26
Response
cirEmCirEmPvcIfA, cir-
EmCirEmPvcIfB
The PVC connection
between two circuit emula-
tion interfaces has been torn
down.
cirEmSpvcConfig-
FailNotify
Interface
Event, 21
Information
interfaceIndex, spvcCo-
nfigFailureCode
An attempt to configure an
endpoint as a CE SPVC end-
point has failed.
cirEmSpvcConfig-
uredNotify
Interface
Event, 20
Information
interfaceIndex
An endpoint has been con-
figured as a CES SPVC end-
point.
cirEmSpvcDelet-
edNotify
Interface
Event, 22
Information
interfaceIndex
A CE SPVC configuration
has been deleted.
cirEmSpvcModi-
fiedNotify
Interface
Event, 23
Information
interfaceIndex
An SPVC endpoint has been
modified. This trap has been
obsoleted 07/01/2001.
cirEmSpvcModi-
fyFailNotify
Interface
Event, 24
Information
interfaceIndex, spvcCo-
nfigFailureCode
An attempt to modify a CE
SPVC endpoint has failed.
This trap has been obsoleted
07/01/2001.
completeClock-
FailedNotify
System
Event, 17
Critical
< NO OBJECTS >
The Stratum 3–4 modules
have either been removed
or have failed, resulting in
no clock being provided.
Possible Cause:
The chassis may have been powered up without installing Stra-
tum 3–4 modules
Corrective Action:
Verify in the equipment configuration whether the Stratum
3–4 modules are installed. The chassis may reboot without the Stratum 3–4 mod-
ules in which case the only way to verify status is through visual inspection of the
chassis.
Table A-2. SNMP Trap Names and Descriptions with Associated MIB Object Names (Continued)
Enterprise-Specific
Trap Name
Trap Group
and
Trap Index
Number
System
Indicator for
the Trap
MIB Object Name
Trap Description
Содержание PacketStar PSAX 4500
Страница 721: ......
Страница 722: ...Part Number 4500M0A8001A2 Copyright 2002 Lucent Technologies All rights reserved ...