255-700-239
A-15
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
Appendix A SNMP Trap Messages
Viewing Trap Log Information
chassisOverTem-
pAlarmNotify
System
Event, 60
Critical
chassisOverTempAlarm-
ReasonCode
Sent by the Stratum 3–4
module when the tempera-
ture of the chassis exceeds
50 degrees Celsius. When a
variance of more than 5
degrees occurs, an error
message is displayed at the
bottom of the console win-
dow. Applicable to the
PSAX 1000, 2300, and 4500
systems only.
Possible Cause:
A rise in chassis temperature may occur if the fan assembly has
failed, or a problem in the Stratum 3–4 module—used to regulate operation of the
fan (in PSAX 4500)—may be malfunctioning.
Corrective Action:
Check the ambient temperature by viewing the value which
is displayed in the Site Configuration menu (in degrees Celsius). This is not the
same as the chassis temperature. Check the status of the Stratum 3–4 modules,
power supplies, and fan tray assemblies.
cirAtmSpvcCon-
figFailNotify
Interface
Event, 71
Information
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr, spvcConfigFail-
ureCode
An attempt to configure an
endpoint as a CE SPVC end-
point has failed.
cirAtmSpvcCon-
figuredNotify
Interface
Event, 70
Information
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr
An endpoint has been con-
figured as a CES SPVC end-
point.
cirAtmSpvcDelet-
edNotify
Interface
Event, 72
Information
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr, spvcConfigFail-
ureCode
An attempt to configure an
endpoint as a CE SPVC end-
point has failed.
cirAtmSpvcModi-
fiedNotify
Interface
Event, 73
Information
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr
An SPVC endpoint has been
modified. This trap has been
obsoleted 07/01/2001.
cirAtmSpvcModi-
fyFailNotify
Interface
Event, 74
Information
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr, spvcConfigFail-
ureCode
An attempt to modify a CE
SPVC endpoint has failed.
This trap has been obsoleted
07/01/2001.
cirAtm-
SpvcVccSetUpNo-
tify
Connec-
tion Event,
69
Response
spvcAddrIfA, cirAtm-
SpvcVccRemoteCePor-
tAddr, cirAtmSpvcVc-
cIfB,
cirAtmSpvcVccVpiB,
cirAtmSpvcVccVciB
An SPVC connection
between CE and ATM end-
points has been successfully
established.
Table A-2. SNMP Trap Names and Descriptions with Associated MIB Object Names (Continued)
Enterprise-Specific
Trap Name
Trap Group
and
Trap Index
Number
System
Indicator for
the Trap
MIB Object Name
Trap Description
Содержание PacketStar PSAX 4500
Страница 721: ......
Страница 722: ...Part Number 4500M0A8001A2 Copyright 2002 Lucent Technologies All rights reserved ...