Chapter 9 Using System Diagnostics
Running Cell Test Diagnostics
9-8
255-700-239
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
Command
Function
Apply and Configure Pay-
load
Applies the traffic parameters you set, and
displays the Cell Test Payload Configura-
tion window.
Go Back to Diagnostics
Menu
Redisplays the Diagnostics Menu window.
Table 9-3. Field Descriptions for the Cell Test Diagnostics Window
Field Names
Values
Description
Slot
Default:
N/A
Range: The total
number of slots in the
Multiservice Media
Gateway system
Format: numeric
The slot number containing the I/O module con-
figured with the ATM UNI interface that you
want to test.
Port
Default:
N/A
Range: The total
number available, per
module
Format: numeric
The port number on the I/O module configured
with the ATM UNI interface you want to test.
Channel
Default:
N/A
Range: The total
number available, per
module
Format: numeric
The channel number on the I/O module config-
ured with the ATM UNI interface for the port you
want to test.
VPI
Default:
N/A
Range: 0–255
Format: Numeric
The virtual path identifier (VPI) for the channel
you want to test.
VCI/DLCI
Default:
N/A
Range: 32–65535
(VCI); 16–1024
(DLCI)
The virtual channel identifier (VCI) or the data
link connection identifier (DLCI) for the channel
you want to test.
VUNI
Default:
001
Range: 0–255
Format: Numeric
The virtual UNI (VUNI) associates itself with the
egress part of the A2B or B2A side of the connec-
tion.
Service Type
Default:
Ubr
Vbr-nrt2, Vbr-
nrt1,Vbr-rt2, Vbr-
rt1, Vbr-express,
Cbr4, Cbr3, Cbr2,
Cbr1
The service type you have set up for the connec-
tion.
Flow
Default:
SimplexTx
SimplexRx, Duplex
The type of traffic flow you want to set up for the
test: one-way transmit, one-way receive, or two-
way flow.