Chapter 5 Site-Specific Configuration
Configuring the System for Your Site
5-20
255-700-239
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
Begin
1
On the Site-Specific Configuration window, enter the values in the fields
on the SNMP Trap Destinations panel for NMS 1 according to the infor-
mation provided in Table 5-10.
2
Repeat step 1 for each network management station you want to define
(up to a total of five).
3
Select the
Apply Site-Specific Configuration
command.
After you apply (save) the values on this window, the system does the
following:
•
Saves the values you entered to the PSAX system database
•
Displays your site name in the upper right corner of the window
•
Displays the local time in the [Local Time] field.
4
To return to the Console Interface Main Menu window, press
Ctrl+G.
End
Table 5-10. Field Descriptions for the SNMP Trap Destinations Panel
Field Name
Field Values
Description
Manager
(display only)
Default:
N/A
Range: NMS 1 to
NMS 5
Format: predefined
alphanumeric
Identifies the first through fifth network manage-
ment systems to which you want SNMP trap
messages to be sent.
Mgr. Addr.
Default:
000.000.
000.000
Range: 000–255
Format: valid dotted
quad
Specifies the IP address of the network manage-
ment system to which you want SNMP trap mes-
sages to be sent.