Installation Tests
Local Equipment and Cross-connect Tests
4 - 2 4
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 24
Click on the
upd-sys
command.
............................................................................................................................................................................
Step 25
Click
Send
to issue the command.
............................................................................................................................................................................
Step 26
The flashing fault LED on the LNW71 (10/100-PL), or LNW66 (10/
100T) (R1.1) will clear and any alarms on the Metropolis
®
DMXtend
shelf will also clear.
............................................................................................................................................................................
Step 27
Click on the
dlt-vlan
command.
............................................................................................................................................................................
Step 28
Under the
Parameters
section, click
fn-{d}-1
from the choices given
under the
<VLANAID>
column.
............................................................................................................................................................................
Step 29
Double click on the
d
portion of the
fn-{d}-1
parameter under the
<VLANAID>
column and click on the letter that corresponds to the
Metropolis
®
DMXtend FN slot of the LNW71 (10/100-PL), or LNW66
(10/100T) (R1.1) under test from the drop down menu that appears.
Result:
At this point a command similar to the following example
should be displayed in the command window to the left of the
Send
button.
Example for Function Unit d:
dlt-vlan:lt-dmxtend:fn-d-1:2::1;
............................................................................................................................................................................
Step 30
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 31
Under the
Parameters
section, click
fn-{d}-1
from the choices given
under the
<VRTSWAID>
column, and then click on
{ 1 }
from the
choices given under the
<VRTSWIDDLT>
column.
Result:
At this point a command similar to the following example
should be displayed in the command window to the left of the
Send
button.
Example for Function Unit d:
dlt-vrtsw:lt-dmxtend:fn-d-1:2::1;