Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
2 - 1 2
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Initial Circuit Pack Installation
Description
This section provides instructions for installing, BUT NOT fully
seating, circuit packs into the Metropolis
®
DMXtend shelf. After circuit
packs have been unpacked, they may be placed in their respective slots
in the Metropolis
®
DMXtend shelf but NOT FULLY ENGAGED IN
THE BACKPLANE CONNECTOR. The circuit packs will be fully
installed (seated) in the section, Circuit Pack Installation (page 3-4).
Important!
If office alarms are connected, it is advisable to
disconnect the office alarm cable while performing the procedures
in this section to prevent spurious alarms from being reported.
Reconnect the office alarm cable after completion of all testing.
CAUTION
177D or LNW98 Apparatus Blanks are required in all
unequipped D and G Function Unit slots to provide proper air
flow for cooling.
LNW42 or LNW95 (R1.1) Apparatus Blanks are required in all
unequipped Main slots to provide proper air flow for cooling.
LNW43 or LNW96 (R1.1) Apparatus Blanks are required in all
unequipped A/B slots to provide proper air flow for cooling.
CAUTION
To protect against damage due to electrostatic discharge, a
properly grounded ESD wrist strap must be worn when handling
equipment.
LNW1 (SYSCTL)
Installation
Follow this procedure to install the LNW1 (SYSCTL) circuit pack into
the Metropolis
®
DMXtend shelf.
Step 1
Remove the SYSCTL circuit pack from the packing material.
............................................................................................................................................................................
Step 2
Identify the
CTL
slot on the Metropolis
®
DMXtend shelf. See