Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
...........................................................................................................................................................................................................................................................
2 - 1 9
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 7
Repeat Step 1 through Step 6 for each additional function group and/or
growth slot to be equipped with LNW37 (OC-3 SFP OLIU) circuit
packs.
............................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps
Install SFP (Small Form-
Factor Pluggable) Optics
Step 1
Determine the OLIU circuit pack and socket being equipped with the
pluggable optics module.
Important!
Pluggable optics modules are shipped with a water-
tight process plug installed into the optical ports to maintain
cleanliness during storage and/or transportation. It is
recommended that the process plug be kept in place to maintain
cleanliness until the optical fiber is connected. With proper care
and handling, cleaning the pluggable optics modules should not be
necessary.
............................................................................................................................................................................
Step 2
Check the ports for cleanliness and clean the pluggable optics module
if necessary. See Appendix B.
............................................................................................................................................................................
Step 3
Remove the water-tight process plug from the optics module and
orient/line up the optics module’s LC connector with the LC connector
label on the OLIU circuit pack faceplate marked input and output. (do
not insert optics module). Then replace the water-tight process plug.
............................................................................................................................................................................
Step 4
Insert the pluggable optics module in the required socket of the OLIU
circuit pack faceplate, then wiggle the optics module to verify that it is
locked in the socket. Verify that all unused sockets are equipped with
dust covers.
Result:
The port appears in the WaveStar
®
CIT
System View
indicating successful installation.