49
Function list
Fun
ctio
ns
List
Function group 2
LED
display
Address
for
communi-
cation
Parameter
name
Min/
Max
range
Description
Factory
defaults
Adj.
during
run
Page
H27
A31B
[Auto Restart
time]
0-60
[sec]
This parameter sets the time between
restart tries.
1.0
O
H30
A31E
[Motor type
select]
0.2-
22.0
0.2
0.2kW
7.5
1)
X
-
-
22.0
22.0kW
H31
A31F
[Number of
motor poles]
2 - 12
This setting is displayed via rPM in drive
group.
4
X
H32
A320
[Rated slip
frequency]
0 - 10
[Hz]
120
P
rpm
f
f
r
s
Where,
s
f
= Rated slip frequency
r
f
= Rated frequency
rpm
= Motor nameplate RPM
P
= Number of Motor poles
2.33
2)
X
H33
A321
[Motor rated
current]
0.5-
150
[A]
Enter motor rated current on the
nameplate.
26.3
X
H34
A322
[No Load
Motor Current]
0.1-
100 [A]
Enter the current value detected when
the motor is rotating in rated rpm after the
load connected to the motor shaft is
removed.
Enter the 50% of the rated current value
when it is difficult to measure H34
– [No
Load Motor Current].
11
X
H36
A324
[Motor
efficiency]
50-
100
[%]
Enter the motor efficiency (see motor
nameplate).
87
X
H37
A325
[Load inertia
rate]
0 - 2
Select one of the following according to
motor inertia.
0
X
0
Less than 10 times
1
About 10 times
2
More than 10 times
1)
H30 is preset based on inverter rating.
2)
H32 - H36 factory default values are set based on OTIS-LG motor.
www.barghmaher.ir
Содержание iG5H Series
Страница 13: ...www barghmaher ir ...
Страница 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Страница 23: ...10 Installation Wiring www barghmaher ir ...
Страница 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Страница 173: ...Protective functions 160 www barghmaher ir ...
Страница 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Страница 223: ...210 www barghmaher ir ...
Страница 225: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 www barghmaher ir ...