Advanced functions
125
Adv
anc
ed
Fun
ctio
ns
8.20 Auto restart try
Group
Code
Parameter Name
Setting Range Default Unit
Function
group 2
H26
[Number of Auto Restart try] -
0 - 10
0
H27
[Auto Restart time]
-
0 - 60
1.0
sec
This parameter sets the number of times auto restart is activated in H26.
It is used to prevent the system down caused by internal protection function activated
by the causes such as noise.
►
H26: Auto restart will become active after the H27. H26
– [Number of Auto restart try] is
reduced by 1 when it is active. If the trip outnumbers the preset restart try, auto restart
function is deactivated. If the setting is reset via the control terminal or the STOP/RST
key on the keypad, the number of auto restart try set by user is automatically entered.
►
If there is no more trip occurring for 30 sec after Auto restart operation, the H26 is
restored to the preset value.
►
When operation is stopped due to Low voltage {Lvt} or Emergency stop {EST}, Inverter
Overheat {Oht}, and Hardware Trip {HWt}, Auto restart will be deactivated.
►
After the H27- [Auto Restart time], the motor starts acceleration automatically via speed
search (H22-25).
www.barghmaher.ir
Содержание iG5H Series
Страница 13: ...www barghmaher ir ...
Страница 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Страница 23: ...10 Installation Wiring www barghmaher ir ...
Страница 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Страница 173: ...Protective functions 160 www barghmaher ir ...
Страница 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Страница 223: ...210 www barghmaher ir ...
Страница 225: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 www barghmaher ir ...