73
Basic Functions
Bas
ic
Fun
ctio
ns
Frequency setting via –10 - +10[V] input
7.1.3
Group
Code
Parameter Name
Setting
Range
Default Unit
Drive group
0.00
[Frequency Command]
-
0 -400
0.00
Hz
Frq
[Frequency Mode]
2
0 - 8
0
I/O group
I 2
[NV input minimum voltage]
-
0 - -10
0.0
V
I 3
[Frequency corresponding to
I2]
-
0 - 400
0.00
Hz
I 4
[NV input max voltage]
-
0 - 10
10.00
V
I 5
[Frequency corresponding to
I4]
-
0 - 400
60.00
Hz
I6 - I10
[V1 input]
Set
Frq
– [Frequency Mode] to 2.
The set frequency can be monitored in
0.00
- [Frequency Command].
►
Apply
–10V - +10V signal between V1 and CM terminal.
►
Output frequency corresponding to
–10V - +10V input voltage to V1 terminal
►
I 2 - I 5: Setting input range and corresponding frequency to -10V - 0V V1 input voltage
Ex) when minimum (-) input voltage is -2V with corresponding frequency 10Hz and Max
voltage is
–8V with run freq. 50Hz.
www.barghmaher.ir
Содержание iG5H Series
Страница 13: ...www barghmaher ir ...
Страница 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Страница 23: ...10 Installation Wiring www barghmaher ir ...
Страница 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Страница 173: ...Protective functions 160 www barghmaher ir ...
Страница 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Страница 223: ...210 www barghmaher ir ...
Страница 225: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 www barghmaher ir ...