Learning to Perform
Basic Operations
68
3.2.8 Setting the Monitor Display Items
In Monitor mode, 3 different items may be monitored at once. Certain monitor items, such
as the frequency reference, are selectable. The display items to be displayed on the screen
can be selected by the user in the Config (CNF) mode. However, in HAND mode or in OFF
mode, the first display item is permanently fixed as the frequency reference. On the top-
right corner of the keypad display‘s status bar, another frequency item is displayed. This
item refers to the frequency reference when the inverter is not operating and the output
frequency when the inverter is operating.
The following example shows how to configure the display items in HAND mode.
•
Monitor mode is displayed on the keypad. The output
frequency, output current, and output voltage are
displayed (factory default).
•
Go to the Config (CNF) mode. In the Config mode,
codes CNF-21
–23 are used to select the three
monitoring display items. The currently selected
display item and its setting are highlighted.
•
To view the available display items and change the
setting for the third monitoring display item, press the
[Down] key to move to CNF-23 and press the
[PROG/ENT] key.
•
The currently selected display item for CNF-23
(Monitor Line
–3) is ‗Output Voltage.‘
•
Press the [Up] or [Down] key to view the available
display items.
•
Move to ‗4 Output Power‘ and press the [PROG/ENT]
key to change the setting.
Содержание H100
Страница 14: ......
Страница 18: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 27: ...Preparing the Installation 13 ...
Страница 47: ...33 Installing the Inverter ...
Страница 48: ...Installing the Inverter 34 Input and Output Control Terminal Block Wiring Diagram ...
Страница 61: ...47 Installing the Inverter ...
Страница 71: ...Learning to Perform Basic Operations 57 ...
Страница 88: ...Learning to Perform Basic Operations 74 ...
Страница 103: ...89 Learning Basic Features Code Description V1 Quantizing ...
Страница 120: ...Learning Basic Features 106 Grou p Cod e Name LCD Display Parameter Setting Setting Range Unit Prev ...
Страница 129: ...115 Learning Basic Features ...
Страница 140: ...Learning Basic Features 126 ...
Страница 148: ...Learning Basic Features 134 ...
Страница 171: ...157 Learning Advanced Features Deceleration dwell operation ...
Страница 183: ...169 Learning Advanced Features ...
Страница 184: ...Learning Advanced Features 170 PID Command Block ...
Страница 185: ...171 Learning Advanced Features PID Feedback Block ...
Страница 186: ...Learning Advanced Features 172 PID Output Block ...
Страница 187: ...173 Learning Advanced Features PID Output Mode Block ...
Страница 197: ...183 Learning Advanced Features ...
Страница 201: ...187 Learning Advanced Features Code Description 100 EPID1 Control block ...
Страница 202: ...Learning Advanced Features 188 EPID2 Control block ...
Страница 237: ...223 Learning Advanced Features Time Period Schedule AP3 38 Except3 Day 01 01 ...
Страница 244: ...Learning Advanced Features 230 ...
Страница 259: ...245 Learning Advanced Features Code Description Code Description Volt ...
Страница 362: ...Learning Protection Features 348 ...
Страница 415: ...401 RS 485 Communication Features Item Standards Parity check None ...
Страница 524: ...Table of Functions 510 ...
Страница 533: ...Table of Functions 519 ...
Страница 547: ...533 Troubleshooting ...
Страница 564: ...Technical Specification 550 11 3 External Dimensions IP 20 Type 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 585: ...Technical Specification 571 ...
Страница 594: ...580 ...
Страница 595: ...581 ...
Страница 596: ...582 ...