This chapter describes the advanced features of the H100 inverter. Check the reference
page in the table to see the detailed description for each of the advanced features.
Advanced Tasks
Description
Ref.
Auxiliary
frequency
operation
Use the main and auxiliary frequencies in the predefined
formulas to create various operating conditions. Auxiliary
frequency operation is ideal for Draw Operation* as this feature
enables fine-tuning of operation speeds.
Jog operation
Jog operation is a kind of a manual operation. The inverter
operates to a set of parameter settings predefined for Jog
operation while the Jog command button is pressed.
Up-down
operation
Uses the upper and lower limit value switch output signals (i.e.
signals from a flow meter) as Acc/Dec commands to motors.
3-wire operation
3-wire operation is used to latch an input signal. This
configuration is used to operate the inverter by a push button.
Safety operation
mode
This safety feature allows the inverter‘s operation only after a
signal is input to the multi-function terminal designated for the
safety operation mode. This feature is useful when extra care is
needed in operating the inverter using the multi-purpose
terminals.
Dwell operation
Use this feature for the lift-type loads such as elevators, when
the torque needs to be maintained while the brakes are applied
or released.
Slip compensation
This feature ensures that the motor rotates at a constant speed,
by compensating for the motor slip as a load increases.
PID control
PID control provides constant automated control of flow,
pressure, and temperature by adjusting the output frequency of
the inverter.
Sleep-wakeup
operation
When the inverter operation continues below the PID
conditions for a set time period, the PID reference is
automatically raised to extend the operation standby time. This
keeps the inverter in a standby (sleep) mode when the demand
is very low.
Auto-tuning
Used to automatically measure the motor control parameters to
optimize the inverter‘s control mode performance.
Содержание H100
Страница 14: ......
Страница 18: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 27: ...Preparing the Installation 13 ...
Страница 47: ...33 Installing the Inverter ...
Страница 48: ...Installing the Inverter 34 Input and Output Control Terminal Block Wiring Diagram ...
Страница 61: ...47 Installing the Inverter ...
Страница 71: ...Learning to Perform Basic Operations 57 ...
Страница 88: ...Learning to Perform Basic Operations 74 ...
Страница 103: ...89 Learning Basic Features Code Description V1 Quantizing ...
Страница 120: ...Learning Basic Features 106 Grou p Cod e Name LCD Display Parameter Setting Setting Range Unit Prev ...
Страница 129: ...115 Learning Basic Features ...
Страница 140: ...Learning Basic Features 126 ...
Страница 148: ...Learning Basic Features 134 ...
Страница 171: ...157 Learning Advanced Features Deceleration dwell operation ...
Страница 183: ...169 Learning Advanced Features ...
Страница 184: ...Learning Advanced Features 170 PID Command Block ...
Страница 185: ...171 Learning Advanced Features PID Feedback Block ...
Страница 186: ...Learning Advanced Features 172 PID Output Block ...
Страница 187: ...173 Learning Advanced Features PID Output Mode Block ...
Страница 197: ...183 Learning Advanced Features ...
Страница 201: ...187 Learning Advanced Features Code Description 100 EPID1 Control block ...
Страница 202: ...Learning Advanced Features 188 EPID2 Control block ...
Страница 237: ...223 Learning Advanced Features Time Period Schedule AP3 38 Except3 Day 01 01 ...
Страница 244: ...Learning Advanced Features 230 ...
Страница 259: ...245 Learning Advanced Features Code Description Code Description Volt ...
Страница 362: ...Learning Protection Features 348 ...
Страница 415: ...401 RS 485 Communication Features Item Standards Parity check None ...
Страница 524: ...Table of Functions 510 ...
Страница 533: ...Table of Functions 519 ...
Страница 547: ...533 Troubleshooting ...
Страница 564: ...Technical Specification 550 11 3 External Dimensions IP 20 Type 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 585: ...Technical Specification 571 ...
Страница 594: ...580 ...
Страница 595: ...581 ...
Страница 596: ...582 ...