Chapter 3 - Installation
3-1
CHAPTER 3 - INSTALLATION
3.1 Installation precautions
1) Handle the inverter with care to prevent damage to the plastic components. Do
not hold the inverter by the front cover.
2) Do not mount the inverter in a location where excessive vibration (5.9 m/sec
2
or
less) is present such as installing the inverter on a press or other moving
equipment.
3) Install in a location where temperature is within the permissible range (-
10~40
C).
4) The inverter will be very hot during operation. Install it on a non-combustible
surface.
5) Mount the inverter on a flat, vertical and level surface. Inverter orientation must
be vertical (top up) for proper heat dissipation. Also leave sufficient clearances
around the inverter.
However, A = Over 500mm and B = 200mm should be
obtained for inverters rated 30kW and above.
B:5cm
Min
B:5cm
Min
Inverter
A: 10cm Min
A: 10cm Min
Cooling fan
Cooling air
Leave space enough
to allow
cooled air
flowing easily
between wiring duct
and the unit.
Temp.
checking point
Temp.
checking point
5 cm
5 cm
5 cm
Inverter