68/70
“LS Ubiquitous RF-ID System”
Appendix. B Error Response Table
[Table Appendix B-1] Communication error table between Reader and Host (5th Byte
value )
Dec
Response (Error1)
Description
0 noError
Normal Response
1 TagGeneralError
ISO Tag Error
2 noResponseFromTag
No response from Tag
3 ReaderFrameError
Frame length is different from the defined one.
4 ReaderCheckSumError
Check Sum value of Frame is wrong
5 ControlByteError
Unsupported Control Byte is in.
6 CommandNotSupported
Unsupported Command is in.
7 invalidParameter
ISO Command Parameter value is wrong.
8 TagDataLengthError
Tag data length that Reader receives is wrong.
9 TagCRCError
CRC value of Tag data that Reader receives is wrong.
10 BufferOverWritingError
Buffer is Overwriting.
255 UndefinedError
An error occurred, not defined by another code
If station no. is wrong
No response
[Table Appendix B-2] Tag Error Response Message Table
Hex
Description (Error2)
01
The command is not supported, i.e. the request code is not recognized.
02
The command is not recognized, for example: a format error occurred.
03
The command option is not supported.
0F
Error with no information given or a specific error code is not supported.
10
The specified block is not available (doesn’t exist).
11
The specified block is already -locked and thus cannot be locked again
12
The specified block is locked and its content cannot be changed.
13
The specified block was not successfully programmed.
14
The specified block was not successfully locked.
-
Custom command error codes
Содержание LGRF-H
Страница 23: ...23 70 LS Ubiquitous RF ID System 2 4 Product Appearance and Dimension Fig 2 4 1 LGRF H Reader...
Страница 24: ...24 70 LS Ubiquitous RF ID System Fig 2 4 2 LGRF H Reader Fig 2 4 3 Antenna A Type...
Страница 25: ...25 70 LS Ubiquitous RF ID System Fig 2 4 4 Antenna B Type Fig 2 4 5 Antenna C Type...
Страница 69: ...69 70 LS Ubiquitous RF ID System Appendix C PLC Examples 1 Example of MELSEC PLC HEX mode communication...
Страница 70: ...70 70 LS Ubiquitous RF ID System 2 Example of MELSEC PLC ASCII mode communication...