10/70
“LS Ubiquitous RF-ID System”
Chapter 3 Installation
3.1 Range of Temperature and Humidity
Cares should be taken to avoid the temperature rising or generation of static electricity
caused by the failure of air conditioning equipment or unbalance of ventilation and heat
generation, and to keep the following conditions always and avoid the long time operation
under the condition out of the range.
1) Operation temperature : -5 ~ +60
℃
2) Storage temperature : -25 ~ +75
℃
3) Humidity : 20 ~ 80% RH (no dewing)
3.2 Air Cleanness
The amount of dust or particulates indoor should be less than 2mg/
㎥
.
Especially, the indoor should be absolutely free from corrosive gas (H2S, SO, chlorine etc.),
the electric conductive gas (Fe, carbon etc.).
1) H2S : less than 0.01 ppm
2) SO : less than 0.05 ppm
3.3 Vibration Condition
The vibration of installation place shall be less than standard as below.
1) If the vibration frequency is less than 10 ~ 13Hz : vibration displacement less than
0.75mm
2) If the vibration frequency is 13 ~ 100Hz : vibration acceleration less than 1G
WARNING
Nobody is permitted to install, operate and maintain the product
except expert.
It may cause the injury or malfunction.
Содержание LGRF-H
Страница 23: ...23 70 LS Ubiquitous RF ID System 2 4 Product Appearance and Dimension Fig 2 4 1 LGRF H Reader...
Страница 24: ...24 70 LS Ubiquitous RF ID System Fig 2 4 2 LGRF H Reader Fig 2 4 3 Antenna A Type...
Страница 25: ...25 70 LS Ubiquitous RF ID System Fig 2 4 4 Antenna B Type Fig 2 4 5 Antenna C Type...
Страница 69: ...69 70 LS Ubiquitous RF ID System Appendix C PLC Examples 1 Example of MELSEC PLC HEX mode communication...
Страница 70: ...70 70 LS Ubiquitous RF ID System 2 Example of MELSEC PLC ASCII mode communication...