45/70
“LS Ubiquitous RF-ID System”
[Table 4.2.1.2] Description of each item of Sending Frame
No.
Items
Description
1
Start Byte
Byte indicating the start of Sending Frame (displayed as F0)
2
Station ID
Station no. given to Reader (which adjusts the value of rotary
switch next to Reader.)
3
Data Length
Total length of Frame (from Start Byte to Check Sum)
4
Control Mode
Mode to select the control environment of Reader
5
Command
Command according to each Control Mode
6
LSB
Determined by Command and Control value
7
Check Sum
Check Sum value
Control Mode, 4
th
item of sending frame from the above table, determines whether the next
Frame command is the Frame to configure the Reader (0x01) or Tag control command by using
the Reader (0x02), or it controls the Tag directly (0x03) based on ISO 15693. [Table 4.2.1.3]
below shows the classification of Control Mode. And Command of 5
th
item is consisted of the
items that perform various commands following each control mode.
(For detailed information, please refer to “LGIS RF-ID Reader Environement Setting & Host
Protocol Manual”)
[Table 4.2.1.3] Control Mode classification
Control Mode classification
Code value (HEX)
1
Reader Environment Setting Protocol Mode
0x01
2
Reader Control Protocol Mode
0x02
3
ISO tag Protocol Mode
0x03
4
Buffer Read Protocol
0x04
5
ISO Extention Protocol
0x05
6 Scaner
Mode
0x06
[Table 4.2.1.4] below shows the Receiving Frame Structure when Reader performed the
normal communication operation. And [Table 4.2.1.5] shows the description of each item of
normal Receiving Frame Structure.
Содержание LGRF-H
Страница 23: ...23 70 LS Ubiquitous RF ID System 2 4 Product Appearance and Dimension Fig 2 4 1 LGRF H Reader...
Страница 24: ...24 70 LS Ubiquitous RF ID System Fig 2 4 2 LGRF H Reader Fig 2 4 3 Antenna A Type...
Страница 25: ...25 70 LS Ubiquitous RF ID System Fig 2 4 4 Antenna B Type Fig 2 4 5 Antenna C Type...
Страница 69: ...69 70 LS Ubiquitous RF ID System Appendix C PLC Examples 1 Example of MELSEC PLC HEX mode communication...
Страница 70: ...70 70 LS Ubiquitous RF ID System 2 Example of MELSEC PLC ASCII mode communication...