54/70
“LS Ubiquitous RF-ID System”
EX1) Read the zero Block of Tag as Single Block Read.
Sending Frame
: F0 00 08 03 03 20 00 1E
Receiving Frame
:
F0 00 0A 03 00 31 32 33 34 C7
Zero Block Data : assumed by 31 32 33 34 (Hex)
Size of one Block of Tag :4 Bytes
z
Sending Frame Structure
No.
Items
Value
Description
1 Start
Byte
F0
Byte indicating the start of Sending Frame (set as F0)
2 Station
ID
00
Station no. given to Reader (matching with the value of rotary
switch next to Reader)
3 Data
Length
08
Total length of Frame (from Start Byte to Check Sum)
4 Control
Mode
03
Sets 03 among Control Modes in order to control Tag directly
based on ISO 15693.
5 Flags
03
ISO 15693 Flag value
6 Command
20
Sets 20 of Single Block Read Command among ISO 15693
Commands.
7 Baddr
00
Marks the address of relevant block to perform Block Read.
As here, it is zero Block, it is set as ‘00’.
8 Check
Sum
1E
Calculate Check Sum value and mark the low 8 bit value.
z
Receiving Frame Structure (normal receiving)
No.
Items
Value
Description
1 Start
Byte
F0
Byte indicating the start of Receiving Frame (set as F0)
2 Station
ID
00
Station no. given to Reader (the value of rotary switch next to
Reader is shown.)
3 Data
Length
0A
Total length of Frame (from Start Byte to Check Sum)
4 Control
Mode
03
Control Mode selected by Receiving Frame is displayed.
5 Error
Code
00
At normal Receiving Frame, ‘00’ (For the value except this,
refer to Error Code.
Appendix B
)
6~9 Bdata
31~34
Reads the data written in zero Block (4 Bytes).
10 Check
Sum
C7
Calculate Check Sum value and mark the low 8 bit value.
Содержание LGRF-H
Страница 23: ...23 70 LS Ubiquitous RF ID System 2 4 Product Appearance and Dimension Fig 2 4 1 LGRF H Reader...
Страница 24: ...24 70 LS Ubiquitous RF ID System Fig 2 4 2 LGRF H Reader Fig 2 4 3 Antenna A Type...
Страница 25: ...25 70 LS Ubiquitous RF ID System Fig 2 4 4 Antenna B Type Fig 2 4 5 Antenna C Type...
Страница 69: ...69 70 LS Ubiquitous RF ID System Appendix C PLC Examples 1 Example of MELSEC PLC HEX mode communication...
Страница 70: ...70 70 LS Ubiquitous RF ID System 2 Example of MELSEC PLC ASCII mode communication...