Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 28
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
7.10
Menu item „Pellethopper Refill“
Hopper: full:
Here, the status of the "inititator" (full detector) in the pellet hopper that is mounted on the boiler is
displayed.
Insertion times: 1. 08:00 2. 11:00 3. 15:00 4. 19:30:
4 insertion times can be set.
The refill starts when the actual time has met one of the 4 set insertion times and "Hopper: not
full" is displayed.
NOTICE 1: If the hopper gets empty between the insertion times (e.g. the points are set too far
apart), insertion can be executed beyond those times if the outside temperature falls below 6°C
between 5 o'clock and 23 o'clock.
If the frost protection function is active, emergency insertion can take place at any time.
NOTICE 2: In regular intervals (depending on pellets consumption), an automatic pellet hopper
cleaning is executed. For this purpose, the automatic pellet hopper refill is blocked (shown by a
information message) until the hopper is drained empty. Subsequently, an off-schedule insertion
can be executed between 5 o'clock and 23 o'clock if outside temperature falls below 6°C; otherwise
between 8 o'clock and 21 o'clock.
During hopper draining, particles accumulated in the hopper during operation are burned.
Feedingsystem: ON
If you switch from "ON" to "OFF", the Feedingsystem is deactivated.
In this case, the information message "Feeding system OFF! To activate at menu-item “Pellet Refill”
is displayed.
10:01:
Here, the actual time is displayed.
Instant Refill
Via "Inst.Refill", the hopper is refilled immediately,
(set field on the text, push button
), feeding system starts immediately; premise: Display
"Hopper: not full".