SPACE 2000 EVO/N (T and M versions) OPERATION MANUAL
19
STORED DATA CLEARING
This function can be used to cancel the data entered by the operator, either globally or
selectively. The instrument has placed them in 11 different storage areas.
Key
0
And if required
+
-
The indications concerning the types of data stored in the memory areas will be displayed,
together with the number corresponding to each area. If the keys indicated are pressed on
the keypad of the instrument::
1:
All the data stored are cancelled.
8:
Rotative speed is deleted
2:
The
data
concerning
linear
corrections
and
scale
factor
corrections are cancelled and these
are reset to a value of 1 (that is to
say, no correction).
9:
10:
11:
Inclined constant pitch is deleted
Circular flange is deleted.
Special circular flange is deleted
3:
Both
the
absolute
and
the
incremental
dimensions
and
references are cancelled.
4:
The offsets are cancelled.
5:
The orignins are cancelled
6:
The weight of materials is cancelled.
7:
The constant pitch is cancelled.
Each time one of the numbers
indicated above
is pressed, the function will be carried
out, while for the functions without a code it is necessary to enter EXE.