Direct Vent Terminal Location

Plan the vent system layout so that proper clearances are maintained
from plumbing and wiring.  Before the vent is installed, determine the vent
pipe termination location as shown below in Figure 10.

Vent terminals must terminate at least 3 feet 

 (0.9 m)

 above any forced air inlet

located within 10 feet 

 (3.1 m)

.  This provision does not apply to:

1. The combustion air intake of a direct vent appliance or the circulating air

inlet and flue gas discharge of listed outdoor appliances.

2. The exhaust vent terminal must be installed with at least  12 inches 

(30 cm)

clearance from any air opening into a building.

3. The bottom of the exhaust vent and combustion air intake terminals must

be located at least 12 inches 

(30 cm) 

above grade and above the anticipated

snow level.

4. Must be installed at least 3 feet 

(0.9 m)

 from any gas meter, gas valve or

other gas regulating equipment.Must be installed in a location where it will
not be blocked by snow.

5. The exhaust vent and combustion air intake terminals must be installed so

that the centerline distances are at least 18 inches 

(45.7cm)

 apart and the

exhaust  vent terminal elbow extends 6 inches 

(15.2 cm)

 past the combustion

air intake terminal.

NOTICE

If 4 inch PVC or CPVC pipe is used, then a 4 inch PVC or CPVC screened
intake and exhaust 90° elbow is required.

Figure 10                                                                                                Vent Terminal Location

 

EXCEPTIONS FOR INSTALLATIONS

The vent terminal must not terminate:

1. Directly above a paved sidewalk or paved driveway which is located

between two single-family dwellings and serves both dwellings;

2. Less than 7 feet 

(2.1 m) 

above a paved sidewalk or a paved

driveway located on public property;

3. Within 6 feet

 (1.8 m) 

of a mechanical air supply inlet to any

building;

4. Above a gas meter/regulator assembly within 3 feet 

(0.9 m)

horizontally of the vertical centerline of the regulator;

5. Within 6 feet

 (1.8m) 

of any gas service regulator vent outlet;

6. Less than 1 foot 

(30.5 cm)

 above grade level;

7. Within 12 inches 

(30.5 cm)

 of a window or door, which can be

opened in any building, any non-mechanical air, supply inlet to any
building or the combustion air inlet of any other appliance;

8. Underneath a veranda, porch or deck, unless:

The veranda, porch or deck is fully open on a minimum of two
sides beneath the floor and

The distance between the top of the vent termination and the
underside of the veranda, porch or deck is greater than 1 foot

(30.5 cm)

.

The vent system must terminate so that proper clearances are maintained
as cited in local codes or the latest edition of the National Fuel Gas Code,
ANSI Z223.1.73.4e and 7.8a, b as follows:

1. Do not terminate the exhaust vent terminal over public area where

condensate or vapor can cause nuisance or hazard.

2. For direct vent, the venting system shall terminate at least 1 foot

below, 1 foot horizontally from or 1 foot above any door, window,
or gravity air inlet into building.

Содержание TNR-I&S-02

Страница 1: ...perature and pressure relief valve complies with local codes If the combination temperature and pressure relief valve does not comply with local codes replace it with one that does Install a discharge...

Страница 2: ...ions will be short and direct 2 THIS WATER HEATER IS SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR DO NOT install this water heater on carpeting 3 FOR BASEMENT INSTALLATION provide a solid level elev...

Страница 3: ...pening is to be located within twelve 12 inches of the enclosure top and the bottom opening within twelve 12 inches of the enclosure bottom Each opening shall have a free area of at least one square i...

Страница 4: ...the time it is open Keep clear of the combination temperature and pressure relief valve discharge line outlet The discharge may be hot enough to cause scald injury The water is under pressure and may...

Страница 5: ...injuy and may be used as a guide in determining the safest water temperature for your applications ALTERNATE SPACE HEATING WATER CONNECTIONS Connect the system supply and return piping to the water he...

Страница 6: ...on instructions Water heater must be protected from freezing downdrafts during shutdown periods Provide protection of the building materials from degradation by flue gases from the exhaust vent termin...

Страница 7: ...IONS FOR INSTALLATIONS The vent terminal must not terminate 1 Directly above a paved sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings 2 Less th...

Страница 8: ...de wall if vented on the same wall 2 Use the proper PVC cement to secure the 90 exhaust vent and air intake terminals provided with the water heater to the plastic pipes The distance between the back...

Страница 9: ...0 elbow referred to as the exhaust vent terminal and the air intake terminal Power Vent Terminal Location Refer to the Direct Vent Terminal Location see page 7 section previously mentioned to determin...

Страница 10: ...tical run and every 3 feet of horizontal run of vent pipe length Stress levels in the pipe and fittings can be significantly increased by improper installation If rigid pipe clamps are used to hold th...

Страница 11: ...other appliance Using this kit on other appliances and or water heaters can result in property damage personal injury or death DO NOT operate this water heater until the installation and assembly of t...

Страница 12: ...pipe See Figure 19 5 Install concentric Y fitting and pipe assembly through the structure s hole and field supplied roof boot flashing Do not allow insulation or other materials to accumulate inside p...

Страница 13: ...7 Take the time and effort to do a professional job Shortcuts will only cause you problems and delays in start up The majority of failures in these systems are the result of shortcuts and or improper...

Страница 14: ...any damage or injury caused as a result of a cracked gas inlet as a result of excessive torque This water heater and its gas connection must be leak tested before placing the water heater in operatio...

Страница 15: ...at satisfied 4 Blower pre purge 9 Main burner OFF 5 Igniter warm up 10 Blower post purge WARNING Water heaters are heat producing appliances To avoid damage or injury there must be no materials stored...

Страница 16: ...1 6 TNR I S 02 LIGHTING INSTRUCTIONS Figure 24 Lighting Instruction Label...

Страница 17: ...mperature during standby periods Lower water temperatures also extend tank life Remember no water heating system will provide exact temperatures at all times Allow a few days of operation at this sett...

Страница 18: ...em Condensate Line OPERATION Sediment Removal Inspect Check Operation Clean Inlet Screen Inspect Inspect Free of Shrubs Debris Inspect Inspect INTERVAL Monthly Semi Annually Semi Annually As Required...

Страница 19: ...sion Replace with a new valve of the recommended size as necessary A thorough inspection of the valve should be performed at least every three years by removing the temperature and relief valve from t...

Страница 20: ...illed with condensate then replace pressure switch If filled empty hose Is the Collector Limit Switch N C If no then reset switch If this switch trips more than 3 times call service If all items above...

Отзывы: