TNR-I&S-02

 WARNING

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE
NOT CERTAIN OF THE FOLLOWING:

Liquefied petroleum gases/propane gas and natural gas have
an odorant added by the gas supplier that aids in detection of
the gas.

Most people recognize this odor as a “sulfur” or “rotten egg”
smell.

Other conditions, such as “odorant fade” can cause the odorant
to diminish in intensity, or “fade”, and not be as readily
detectable.

If you have a diminished sense of smell, or are in any way
unsure of the presence of gas, immediately contact your gas
supplier from a telephone in another building.

Gas detectors are available. Contact your gas supplier or
plumbing professional for more information.

Liquefied petroleum gases/propane gas is heavier than air and will
remain at floor level if there is a leak. Basements, crawl spaces,
closets and areas below ground level will serve as pockets for
accumulation of leaking gas. Before lighting, smell all around the
appliance area for gas.  Be sure to smell next to the floor.

IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any telephone in
your building.

Immediately call your gas supplier from a telephone in another
building.  Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire
department.

DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS
CORRECTED!

INSTALLATION INSTRUCTIONS

Locating The Water Heater

1. LOCATE so that venting connections will be short and direct.
2. THIS WATER HEATER IS SUITABLE FOR INSTALLATION ON COMBUSTIBLE

FLOOR. 

 DO NOT

 install this water heater on carpeting.

3. FOR BASEMENT INSTALLATION, provide a solid level elevated base

such as concrete.

4. Minimum clearance to combustible material is 0" for the Top, Sides

and Rear of this water heater.  However, it is recommended that 

at

least 18" from the Top, 24" from the Front, and 4" for the
Sides and Rear of the water heater be provided for servicing.

Clearance for servicing may be reduced down to minimum clearance
to combustible material, but service time and effort may be greatly
increased.

LOCATION

KEEP APPLIANCE AREA CLEAR AND FREE OF COMBUSTIBLE
MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.

 WARNING

This water heater must be located in an area where leakage of the
tank, water line connections, or the combination temperature and
pressure relief valve will  not result in damage to the area adjacent to
the water heater or to lower floors of the structure.  When such locations
cannot be avoided, a suitable drain pan must be installed under the
water heater.  The drain pan depth must be suitable for draining and
collecting water, and have a minimum length and width of at least four
(4) inches 

(10.0 cm) 

measured from the jacket of the water heater.

The drain pan, as described above, can be purchased from your
plumbing professional.  The drain pan must be piped to an adequate
drain.  The piping must be at least ¾ inch 

(2.0 cm) 

in diameter and

pitched for proper drainage.

 

 Figure 1                                                                                 Minimum Clearance To Combustible

This water heater must be located in an area where the general public does
not have access to set temperatures.

Содержание TNR-I&S-02

Страница 1: ...perature and pressure relief valve complies with local codes If the combination temperature and pressure relief valve does not comply with local codes replace it with one that does Install a discharge...

Страница 2: ...ions will be short and direct 2 THIS WATER HEATER IS SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR DO NOT install this water heater on carpeting 3 FOR BASEMENT INSTALLATION provide a solid level elev...

Страница 3: ...pening is to be located within twelve 12 inches of the enclosure top and the bottom opening within twelve 12 inches of the enclosure bottom Each opening shall have a free area of at least one square i...

Страница 4: ...the time it is open Keep clear of the combination temperature and pressure relief valve discharge line outlet The discharge may be hot enough to cause scald injury The water is under pressure and may...

Страница 5: ...injuy and may be used as a guide in determining the safest water temperature for your applications ALTERNATE SPACE HEATING WATER CONNECTIONS Connect the system supply and return piping to the water he...

Страница 6: ...on instructions Water heater must be protected from freezing downdrafts during shutdown periods Provide protection of the building materials from degradation by flue gases from the exhaust vent termin...

Страница 7: ...IONS FOR INSTALLATIONS The vent terminal must not terminate 1 Directly above a paved sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings 2 Less th...

Страница 8: ...de wall if vented on the same wall 2 Use the proper PVC cement to secure the 90 exhaust vent and air intake terminals provided with the water heater to the plastic pipes The distance between the back...

Страница 9: ...0 elbow referred to as the exhaust vent terminal and the air intake terminal Power Vent Terminal Location Refer to the Direct Vent Terminal Location see page 7 section previously mentioned to determin...

Страница 10: ...tical run and every 3 feet of horizontal run of vent pipe length Stress levels in the pipe and fittings can be significantly increased by improper installation If rigid pipe clamps are used to hold th...

Страница 11: ...other appliance Using this kit on other appliances and or water heaters can result in property damage personal injury or death DO NOT operate this water heater until the installation and assembly of t...

Страница 12: ...pipe See Figure 19 5 Install concentric Y fitting and pipe assembly through the structure s hole and field supplied roof boot flashing Do not allow insulation or other materials to accumulate inside p...

Страница 13: ...7 Take the time and effort to do a professional job Shortcuts will only cause you problems and delays in start up The majority of failures in these systems are the result of shortcuts and or improper...

Страница 14: ...any damage or injury caused as a result of a cracked gas inlet as a result of excessive torque This water heater and its gas connection must be leak tested before placing the water heater in operatio...

Страница 15: ...at satisfied 4 Blower pre purge 9 Main burner OFF 5 Igniter warm up 10 Blower post purge WARNING Water heaters are heat producing appliances To avoid damage or injury there must be no materials stored...

Страница 16: ...1 6 TNR I S 02 LIGHTING INSTRUCTIONS Figure 24 Lighting Instruction Label...

Страница 17: ...mperature during standby periods Lower water temperatures also extend tank life Remember no water heating system will provide exact temperatures at all times Allow a few days of operation at this sett...

Страница 18: ...em Condensate Line OPERATION Sediment Removal Inspect Check Operation Clean Inlet Screen Inspect Inspect Free of Shrubs Debris Inspect Inspect INTERVAL Monthly Semi Annually Semi Annually As Required...

Страница 19: ...sion Replace with a new valve of the recommended size as necessary A thorough inspection of the valve should be performed at least every three years by removing the temperature and relief valve from t...

Страница 20: ...illed with condensate then replace pressure switch If filled empty hose Is the Collector Limit Switch N C If no then reset switch If this switch trips more than 3 times call service If all items above...