PREVENTIVE MAINTENANCE… THE
HYDRAULICS SYSTEM
1
CHECK CONDITION OF RETURN FILTER
Check WEEKLY
2
CHECK THE TANK’S FILL LEVEL
Check DAILY
3
CHECK THAT THE SUCTION LINE VALVE IS OPEN
Check DAILY
4
CHECK THE “PLUMBING” FOR ANY EXTERNAL LEAKS
Check DAILY
5
CHECK THE PUMP AND VALVES FOR ANY EXTERNAL
LEAKAGE
Check DAILY
6
CHECK THE ROD CYLINDERS FOR EXTERNAL LEAKAGE
Check DAILY
7
INSPECT THE STEEL TUBES FOR DAMAGE/LOOSE CLAMPS
Check DAILY
8
CHECK THE FIRE EXTINGUISHER TO BE HAVE FULL
CHARGE
Check DAILY
9
INSPECT HOSES FOR ABRASIONS, RUB SPOTS,ETC
Check DAILY
10
REPLACE THE IN-TANK SUCTION STRAINER
Yearly
11
REPLACE THE TANK’S FILLER/BREATHER
Yearly
12
REPLACE THE HYDRAULIC FULID
Every two years
13
PRESSURE WASH THE ENTIRE UNIT
Monthly
14
GREASE THE CONTROL RODS PLASTIC BEARINGS
Weekly
15
IF PTO EQUIPPED….CHECK THAT THE BOLTS THAT
ANCHOR THE PTO TO TRANSMISSION ARE TIGHT AND THAT
THE PUMP-TO-PTO BOLTINGS ARE ALSO TIGHT
Monthly
16
If CRANKSHAFT DRIVEN PUMP….CHECK THAT THE PROP
SHAFT FASTENERS ARE SECURE & TIGHT…AT PUMP AND AT DIESEL
Weekly
HYDRAULIC FLUID IS VERY FLAMMABLE. THE RISK OF A HYDRAULICS
RELATED FIRE CAN BE REDUCED BY ATTENDING TO ANY LEAKAGE
IMMEDIATELY, PRESSURE WASHING ONCE A WEEK, CLEANING OUT
THE DEBRIS THAT BLOWS BY THE EJECTOR (INSIDE OF THE BODY
TO THE FRONT SIDE OF THE EJECTOR BLADE). CARRY A FULLY
CHARGED FIRE EXTINQUISHER ON-BOARD AND TRAIN YOUR
OPERATOR FOR A “PLAN OF ACTION” IN CASE A FIRE DOES HAPPEN.
[Sec02-pg09]