54
Gap Fill
Maximum distance to fill gaps in data along the x-axis, in mils.
For all data types (profile, tracheid, vision), this value determines
the maximum gap between cameras that will be filled by
connecting the data from adjacent cameras. Gaps can occur
when target objects are close to the sensors, or when sensors
are mounted with extra space between each device. For profile
and tracheid cameras, this value also determines the maximum
x-distance for interpolation
between two valid laser spots
when
resampling data within a single camera.
Overlap Blend
Maximum amount of redundant camera information that can be
blended together at the x-boundary between two cameras (mils).
Blending occurs only when the fields-of-view between adjacent
cameras have non-zero overlap.
Tile Width
Y extent (width) of profile, tracheid, and/or vision data sent in
each web message. 2000 mils is recommended to minimize
CPU and networking overhead.
Latency
Determines the latency of messages received at the client by
changing the message buffer size on the station. Standard, or
Low. Note: Low latency mode may use more station resources.
Содержание chroma+scan 3155
Страница 1: ...chroma scan 3x00 Document Version 4 11 12 30...
Страница 14: ...14 3 1 1 Sensors chroma scan 3155 chroma scan 3250 chroma scan 3350...
Страница 31: ...31 5 5 Dimensions and Mounting 5 5 1 chroma scan 3155 Sensor Dimensions...
Страница 32: ...32 5 5 2 chroma scan 3250 Sensor Dimensions...
Страница 33: ...33 5 5 3 chroma scan 3350 Sensor Dimensions...
Страница 52: ...52 Recommended values 20 to 20 default is 0...