This screen prompts for station attributes:
-
Station Type
: Should be left on “Custom” unless instructed otherwise.
-
Serial Number
: Must be unique within a sensor network. Default is acceptable if
it is the only station.
When installing on a Windows 7 system, you may be prompted by Windows for the
driver installation. It is important to check the box “Always trust software from LMI
Technologies” before clicking “OK”. This step ensures that future upgrades loaded
through the FireSync Host Protocol can proceed unimpeded.
7.1.2
PC with Existing Station Software
If the PC contains existing station software installed by other means, the shortcut menu
item in the “Startup” folder of the Start Menu should be deleted first. Then the station
software can be installed to the same location if the existing files are deleted first.
Alternatively, the new software can be installed to a different location, without having to
delete the original files.
7.1.3
Network Interface Configuration
The sensor and client network interfaces should be setup as described in Section 3.1.5.