Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IN-379 Rev F
Revision Date: 11/19/18
6. Aim fixture as required and tighten the 7/16-14 SHC knuckle adjustment bolt using an approximately 38 ft-lbs.(See
Figure 12c)
7. For units with photocontrol receptacle, the fixture mounting/aiming angle must be restricted from 0° to 45° from
horizontal per ANSI C136.10-2010.
8. Energize the luminaire to verify its operation and proper illumination of area.
WARNING: DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE THAN 5
DEGREES FROM VERTICAL. MOUNTING AT AN ANGLE GREATER THAN 5 DEGREES REQUIRES USE OF A
PROPERLY TIGHTENED THRU-BOLT AND LOCKNUT. FAILURE TO CORRECTLY INSTALL COULD RESULT
IN SERIOUS INJURY OR DEATH.
Knuckle adjustment bolt
Figure 12c