6. Loosen two captive screws on cover of the SPA to access the pole mounting area.(See Figure 16)
7. The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the WBA cover
plate on existing hole.
8. Making sure that no wires are pinched, insert the 3/8” lock bolts through the back wall of the fixture housing,
through the cover plate, and then thread into the threaded steel bar (See Figure 17). Tighten the two bolts with a 9/16
socket to 20-30 ft-lbs (overtightening can damage components and void warranties). Make sure that wires are not
pinched and tuck excess wire up into the luminaire mounting area.
9. Reinstall the SPA Cover that was removed in step 6, tighten the two captive screws with the 9/64 Allen wrench to
18-20 in-lbs (overtighten can cause thread stripping and void all warranties).
CAUTION THE NEXT STEPS WILL REQUIRE ASSISTANCE:
10. Make all wiring connections via the supplied wire leads in accordance with NEC and local codes.
11. Place the entire light fixture/cover plate assembly onto the base plate (Figure 14b)and have someone tighten the
top (2) 3/8” x 1-1/4” stainless steel recessed hex set screws (See Figure 18) until 3/8” to 1/4” of the screw threads are
still visible, then the bottom set screws.
12. Now alternating between the top two and bottom two set screws, gently tighten until snug (approximately one
thread will remain showing on each screw)
Threaded
steel bar
Clearance slot
3/8” diameter lock
bolts
SPA Cover captive
screws
SPA Cover
Figure 16
Figure 17
Figure 14b
Figure 18
3/8" x 1-1/4
recessed hex