background image

Installation Instructions
RSX LED

RSX FAO SETTING INSTRUCTIONS

1.    Loosen six  captive  screws  and remove RSX door to access the  FAO setting area (figure 19).   Set aside for re-

installation.

Figure 19

2.    Use flat screw driver to turn FAO dial to get required Lumen output. (See Figure 20)

        See table for settings. (Table 1) 

Figure 20

FAO 

Adjustment 

Dial

©2016 Acuity Brands Lighting, Inc. 
All Rights Reserved. 

Lithonia Lighting Outdoor

One Lithonia Way,  Conyers, GA 30012

Phone: 800-279-8041 Fax: 770-918-1209

www.lithonia.com

         Part  Number: IN-379 Rev F

                  Revision Date: 11/19/18

Содержание RSX1 LED P4

Страница 1: ...laced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for t...

Страница 2: ...uminaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around fixture Avoid covering LED fixtures with insulation foam or other material tha...

Страница 3: ...ing Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Figure 2a Figure 2b Figure 2c Top Hole 1 Loosen two captive screws on cover of the SPA to access the pole mounting area See Figure 1 2 Two mounting bars are included in the installation kit a The shorter bar is used for 8 Lithonia drilling and has 3 holes The top and bottom hole are threaded b The lo...

Страница 4: ...gh the arm slot and into the available threaded hole of the mounting bar See Figure 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the pole on existing hole patterns Insert the wires through the clearance slot shown in Figure 5 and pull them into the pole 6 Ensure luminaire is straight level making sure that no wires are pinched tighten the two bol...

Страница 5: ...RSX LED RSX MAST ARM ADAPTOR INSTALLATION Tools Required Socket wrenches 5 8 Allen wrench 5 16 Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 Ø pole tenon See Figure 7a 2 Use provided set screws and secure the luminaire in required position 3 Use thru bolt hole provided as pilot and drill 1 2 Ø hole on tenon through mast arm from both side See Fi...

Страница 6: ...of the rubber grommet pull them into the wire connection area Replace the rubber grommet back as originally assembled before wire feeding See Figure 8b 8c Figure 8a Figure 8b Figure 8c 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 Re...

Страница 7: ...it Repeat this step for black hot and white neutral wires Select Wago connec tors with matching colored wires coming from SPD See Figure 9a 9b 9c Figure 9b Figure 9a Figure 9c 6 Use cable tie and tie all newly attached wires shown in Figure 10 7 Make sure that wires are not pinched the door gas ket did not move from original position and sits in its groove on the door properly Reinstall the mounti...

Страница 8: ...Bolts while maintaining the correct position of the luminaire to 23 27 ft lbs 11 Energize the luminaire to verify its operation and proper illumination of area WARNING USE AND PROPERLY TIGHTEN THRU BOLT AND NUT FAILURE TO CORRECT LY INSTALL COULD RESULT IN SERIOUS INJURY OR DEATH 7 16 14 Bolt Set Bolts Pole Tenon Thru Bolt Hole Figure 11a Figure 11b 2016 Acuity Brands Lighting Inc All Rights Reser...

Страница 9: ...d evenly tighten the six 6 3 8 16 UNC knuckle tenon set screws to 23 27 ft lbs while maintaining the correct position of the luminaire 3 Cut and splice the wires Recommended cut length is 6 for wires for ease of splicing and securing in the knuckle See Figure 12b 4 Make all wiring connections via the supplied wire leads in accordance with NEC and local codes 5 Push all fixture and supply wires com...

Страница 10: ...lbs See Figure 12c 7 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 8 Energize the luminaire to verify its operation and proper illumination of area WARNING DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE THAN 5 DEGREES FROM VERTICAL MOUNTING AT AN ANGLE GREATER THAN 5 DEGREES REQUIRE...

Страница 11: ...five 5 3 8 16 UNC knuckle tenon set screws to 23 27 ft lbs while main taining the correct position of the luminaire 2 Use upper set screw hole on front face of the knuckle as pilot and drill 1 2 Ø hole on tenon through knuck le See Figure 13a 3 Insert 7 16 14 x 3 3 4 bolt through Knuckle and drilled 1 2 Ø hole on tenon Place 7 16 Center Lock Distorted Thread Locknut onto bolt and tighten se curely...

Страница 12: ...ee Figure 13c 13d 9 Aim fixture as required and tighten the 7 16 14 SHC knuckle adjustment bolt using an approximately 38 ft lbs See Figure 13e 10 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted to 45 from horizontal per ANSI C136 10 2010 11 Energize the luminaire to verify its operation and proper illumination of area WARNING DO NOT MOUNT THE KNUCKLE FI...

Страница 13: ...e 14a and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners by others using the 4 holes located on the outer corners of the base plate Check the base plate to confirm that it is level and plumb in all directions See Figure 14b 3 Prepare the cover plate by ensuring the factory installed gasket is in place on the backside of the cover plate See Figure 15 4 Open up the light...

Страница 14: ...s are not pinched and tuck excess wire up into the luminaire mounting area 9 Reinstall the SPA Cover that was removed in step 6 tighten the two captive screws with the 9 64 Allen wrench to 18 20 in lbs overtighten can cause thread stripping and void all warranties CAUTION THE NEXT STEPS WILL REQUIRE ASSISTANCE 10 Make all wiring connections via the supplied wire leads in accordance with NEC and lo...

Страница 15: ...llation Figure 19 2 Use flat screw driver to turn FAO dial to get required Lumen output See Figure 20 See table for settings Table 1 Figure 20 FAO Adjustment Dial 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 ...

Страница 16: ...8 8 312 40 000 Values are based on the highest performance package for each fixture size FAO device shipped set at maximum setting 8 Lumen values vary by optic type Table 1 2016 Acuity Brands Lighting Inc All Rights Reserved Lithonia Lighting Outdoor One Lithonia Way Conyers GA 30012 Phone 800 279 8041 Fax 770 918 1209 www lithonia com Part Number IN 379 Rev F Revision Date 11 19 18 3 Make sure th...

Отзывы: