Installation
10. Run the red jumper wire (provided with the ∆P transducer kit) from the J8 terminal 32 to J16
terminal 59 (+5 V).
11. Route a two-wire cable from the shutdown control device through a cable gland in a port on the
back of the LCR 600. Secure the cable gland. LC recommends running the cable through
weatherproof conduit.
12. Connect the two wires from the shutdown control device to terminal block J13, terminals 14 and
15.
Current Draw on Shutdown Device
The shutdown device should draw no more than 1 Amp.