Installation
Materials needed for wiring valves with 110 VAC solenoids
These materials are necessary, but are not supplied with the valve:
·
SPST relay switch (1 per solenoid)
·
20 AWG stranded wire (2 per solenoid)
·
Weatherproof flexible conduit, ½" diameter and ½" NPT conduit connectors or cable glands
·
PTFE tape or pipe sealant
To wire 110 VA C solenoids to the LCR 600:
1. Turn off all 100 VAC circuits before beginning the installation.
2. Install the specified relay switch(es) onto one leg of the 110 solenoid power supply circuit.
3. Connect the relay switch on the S1 power supply circuit to terminals 15 and 16 on block J13.
4. Connect the relay switch on the S2 power supply circuit to terminals 17 and 18 on block J13.
Disconnect Power (110VAC)
Turn off all 110VAC circuits before beginningthe installation.
Содержание LectroCount LCR 600
Страница 1: ...LectroCount LCR 600 E3708 E3709 Series...
Страница 13: ...Introduction 13 Dimensions...
Страница 14: ...Introduction...
Страница 27: ...Installation 27 Bench Seats Adjustable for Distance to the Steering Wheel Manufacturer Standard or equivalent...
Страница 42: ...Installation Disconnect Power Disconnect the power before working on the CPU board...
Страница 54: ...Installation...
Страница 61: ...Installation 61...
Страница 63: ...Installation 63...
Страница 72: ...Installation Epson Printer Power Connections LectroCount LCR 600 Power Connections...
Страница 75: ...Installation 75 Bill of Materials External Components...
Страница 76: ...Installation Internal Components...