Power, input, and output (I/O) wiring must be in accordance with the area classification
for which it is used (Class I, Div 2). For North America, installations must be per the U. S.
National Electrical Code, NFPA 70, or the Canadian Electrical Code in order to maintain
Class I, Division 2 ratings. This may require using connections or other adaptations in
accordance with the requirements of the authority having jurisdiction.
To comply with UL Listing requirements, Class 2 power supply, or an isolation power
source and overcurrent protective
device rated 5 Amp max, are required to be installed in the field. (Pour être conforme aux
exigences UL, une alimentation
électrique de classe 2 ou une alimentation électrique isolée et comportant un dispositif de
protection contre la surtension
de 5 ampères ou moins sont requises pour l’installation.)
Peripheral equipment must be suitable for the hazardous location where it is installed.
(L’équipement périphérique doit être adapté des endroits dangereux où il est installé.)
WARNING: Explosion Hazard (AVERTISSEMENT: Risque d’explosion)
Substitution of components may impair suitability for Class I, Division 2 applications. (La
substitution des composantes
peut altérer la conformité aux applications de Classe I, Division 2.)
When in hazardous locations, turn power OFF before replacing or wiring modules.
(Lorsque dans des endroits
dangereux, couper le courant avant de remplacer ou de câbler les modules.)
Do NOT disconnect equipment unless power has been switched OFF or the area is
known to be Non-Hazardous. (Ne
pas déconnecter l’équipement sans couper l’alimentation ou sans s’assurer que la zone
est non-dangereuse.)
WARNING:
Use 3.5 in • lb (0.4 N • m) torque when tightening terminal block screws.
Содержание LectroCount LCR 600
Страница 1: ...LectroCount LCR 600 E3708 E3709 Series...
Страница 13: ...Introduction 13 Dimensions...
Страница 14: ...Introduction...
Страница 27: ...Installation 27 Bench Seats Adjustable for Distance to the Steering Wheel Manufacturer Standard or equivalent...
Страница 42: ...Installation Disconnect Power Disconnect the power before working on the CPU board...
Страница 54: ...Installation...
Страница 61: ...Installation 61...
Страница 63: ...Installation 63...
Страница 72: ...Installation Epson Printer Power Connections LectroCount LCR 600 Power Connections...
Страница 75: ...Installation 75 Bill of Materials External Components...
Страница 76: ...Installation Internal Components...