Installation
To wire a POD to the LCR 600:
1. Attach cable glands and/or conduit connectors to the POD and the LCR 600 port(s).
2. Thread the wires through a piece of weatherproof conduit cut-to-length from the POD port to a
LCR 600 port.
3. Run the weatherproof conduit between the POD and the LCR 600 housing, pull the wires through
the ports, and tighten the connectors.
4. Connect the four POD terminals to four terminals on the J18 terminal block of the LCR 600 CPU
board.
·
POD terminal 20 to LCR 600 terminal 31
·
POD terminal 21 to LCR 600 terminal 34
·
POD terminal 22 to LCR 600 terminal 33
·
POD terminal 23 to LCR 600 terminal 37
Single Channel Pulse Inputs
The LCR 600 is compatible with the many single channel pulsers and amplifiers. For example, the SP714
pulse amplifier.
Pulse Output Devices 1, 2, 3, & 4 Only
This wiring schematic applies to pulse output devices 1 through 4 only.