33
Mount the LectroCount LCR 600
Follow these steps:
1. Place the end of the shaft adapter on the pulser drive shaft located on the bottom of the register.
2. Place the cotter pin through the hole, and bend open the ends of the cotter pin.
3. Lower the register onto the meter, and insert the shaft adapter onto the hex shaft on the meter.
4. Securely bolt down the register.
Apply Anti-seize
Apply anti-seize to all bolt threads to ensure easy removal at a later date.