Installation
A2859-11 Valve and 3-Way Solenoid
A two- stage valve with a S2 solenoid-operated valve and a 3-way solenoid valve attached to the back of
the LectroCount LCR 600. The 3-way solenoid-operated valve is located at the meeting point of two pipes
from the vapor eliminator (one for eliminated vapor and one leading to the spit tank) and one pipe to the
top of the block valve. The S2 solenoid valve is located on a bypass pipe that connects the inlet and outlet
sides of the control valve. It opens while the control valve is closed to supply the dwell flow. This
configuration is typically specified for products that hold vapor in the line such as LPG and NH3.
E-7 Valves
A two stage valve with a S1 and a S2 solenoid-operated valve. The E-7 valve is fitted with one external
pipe to divert product flow to the closing mechanism. To supply a dwell flow, the E-7 redirects the product
around the closed valve using channels molded into its housing. This valve is typically used in refined
fuels applications.
Содержание LectroCount LCR 600
Страница 1: ...LectroCount LCR 600 E3708 E3709 Series...
Страница 13: ...Introduction 13 Dimensions...
Страница 14: ...Introduction...
Страница 27: ...Installation 27 Bench Seats Adjustable for Distance to the Steering Wheel Manufacturer Standard or equivalent...
Страница 42: ...Installation Disconnect Power Disconnect the power before working on the CPU board...
Страница 54: ...Installation...
Страница 61: ...Installation 61...
Страница 63: ...Installation 63...
Страница 72: ...Installation Epson Printer Power Connections LectroCount LCR 600 Power Connections...
Страница 75: ...Installation 75 Bill of Materials External Components...
Страница 76: ...Installation Internal Components...