LTC3882-1
41
Rev A
PMBus COMMAND SUMMARY
Table 7. PMBus Command Summary
COMMAND NAME
CMD
CODE DESCRIPTION
TYPE
PAGED
DATA
FORMAT UNITS NVM
DEFAULT
VALUE
SEE
PAGE
MFR_FAULT_RESPONSE
0xD5 PWM response when
FAULT
n
pin is low.
R/W Byte
Y
Reg
l
0xC0
MFR_OT_FAULT_RESPONSE
0xD6 Internal overtemperature fault response.
R Byte
N
Reg
0xC0
MFR_IOUT_PEAK
0xD7 Maximum I
OUT
measurement since last
MFR_CLEAR_PEAKS.
R Word
Y
L11
A
MFR_RETRY_DELAY
0xDB Minimum time before retry after a fault.
R/W Word
Y
L11
ms
l
350ms
0xFABC
MFR_RESTART_DELAY
0xDC Minimum time RUN pin is held low by
the LTC3882-1.
R/W Word
Y
L11
ms
l
500ms
0xFBE8
MFR_VOUT_PEAK
0xDD Maximum V
OUT
measurement since last
MFR_CLEAR_PEAKS.
R Word
Y
L16
V
MFR_VIN_PEAK
0xDE Maximum V
IN
measurement since last
MFR_CLEAR_PEAKS.
R Word
N
L11
V
MFR_TEMPERATURE_1_PEAK 0xDF Maximum external temperature
measurement since last MFR_CLEAR_
PEAKS.
R Word
Y
L11
°C
MFR_CLEAR_PEAKS
0xE3 Clear all peak values.
Send Byte
N
MFR_PADS_LTC3882-1
0xE5 State of selected LTC3882-1 pads.
R Word
N
Reg
MFR_ADDRESS
0xE6 Specify right-justified 7-bit device
address.
R/W Byte
N
Reg
l
0x4F
MFR_SPECIAl_ID
0xE7 Manufacturer code representing the
LTC3882-1
R Word
N
Reg
0x424X
MFR_FAULT_LOG_STORE
0xEA Force transfer of fault log from operating
memory to EEPROM.
Send Byte
N
MFR_FAULT_LOG_CLEAR
0xEC Clear existing EEPROM fault log.
Send Byte
N
MFR_FAULT_LOG
0xEE Read fault log data.
R Block
N
Reg
MFR_COMMON
0xEF LTC-generic device status reporting.
R Byte
N
Reg
MFR_COMPARE_USER_ALL
0xF0 Compare operating memory with
EEPROM contents.
Send Byte
N
MFR_TEMPERATURE_2_PEAK 0xF4 Maximum internal temperature
measurement since last
MFR_CLEAR_PEAKS.
R Word
N
L11
°C
MFR_PWM_CONFIG_LTC3882-1 0xF5 LTC3882-1 PWM configuration common
to both channels.
R/W Byte
N
Reg
l
0x14
MFR_IOUT_CAL_GAIN_TC
0xF6 Output current sense element
temperature coefficient.
R/W Word
Y
CF
ppm/°C
l
3900ppm/°C
0x0F3C
MFR_TEMP_1_GAIN
0xF8 Slope for external temperature
calculations.
R/W Word
Y
CF
l
1.0
0x4000
MFR_TEMP_1_OFFSET
0xF9 Offset addend for external temperature
calculations.
R/W Word
Y
L11
°C or V
l
0.0
0x8000
MFR_RAIL_ADDRESS
0xFA Specify unique right-justified 7-bit
address for channels comprising a
PolyPhase output.
R/W Byte
Y
Reg
l
0x80
MFR_RESET
0xFD Force full reset without removing power. Send Byte
N
NVM
l
Indicates a command value stored to internal EEPROM using STORE_USER_ALL or restored to RAM from internal EEPROM at power-up or
execution of RESTORE_USER_ALL or MFR_RESET.