14
Power in connection
The MC5 unit is supplied with
a single 30W power adapter
which is sufficient to supply any
configuration of the unit. The MC5-
IP unit has two power input sockets
to allow an auxiliary (redundant)
power adapter to be connected.
There is no on/off switch on the
unit, so operation begins as soon as
a power adapter is connected.
Note: MC5 units require a heavy
duty power adapter at either or both power input connectors. Use only the
adapter supplied with the unit or available from LINDY. Do not use the standard
10W adapters that are supplied with other LINDY products, such as the User
Station.
To connect the power supply
1 Attach the output lead from the power adapter to the
MAIN PWR IN
socket
on the rear panel of the MC5.
2 Connect the IEC connector of the supplied country-specific power lead to
the socket of the power adapter.
3 Connect the power lead to a nearby main supply socket.
4 Repeat steps 1 to 3 for the auxiliary power adapter (using the
AUX PWR IN
socket), if a backup supply is required.
Note: Both the MC5 and its power supply generate heat when in operation and
will become warm to the touch. Do not enclose them or place them locations
where air cannot circulate to cool the equipment. Do not operate the equipment
in ambient temperatures exceeding 40 degrees Centigrade. Do not place the
products in contact with equipment whose surface temperature exceeds 40
degrees Centigrade. Using two power supplies will ensure that each power
supply takes less load and run at a correspondingly cooler temperature.
OPTIONS
1
3
2
4
5V
5V
WARNING
!
RJ45
CON
NECT
ORS
ON
THIS
PANEL
ARE
FOR
CONN
ECTIO
N
TO KVM
EQUIPM
ENT
ONL
Y.
DO
NOT
CONNECT
TO NETW
ORK
OR
TELEPH
ONE
SYSTEM
S
5A
5A
AUX
PWR
IN
MAIN
PWR
IN
CATx
USER
PORT
Made
in
the
U.K.
Indoor
use
only
1
2
3
ON
MC5 rear panel
output lead from
power adapter
POWER
SWITCH
COMPUTER
SYSTEM
CAM
LOCAL
USER
REMOTE
USER
U S
MODEM
/ISDN
POWER
IN
GLOBAL
USER
IP