background image

Section 4                                                                         CAT. 5 Extender Access & Operation

 

 

20 

 

4.1. Cat.5 KVM Extender Features  

 

The modular KVM switch U8/16 offers the option to use it with or without a remote console 

access module. This module may either be a Cat.5 Extender or IP Access solution. 

The Cat.5 Extender solution provides real time KVM access via a dedicated Cat5e/6 cable with 

a maximum length of 300m. When using higher resolutions we suggest the following maximum 

pixel resolution versus length: 1600x1200@75m/ 1280x1024@150m/1024x768@250m  

 

Overall picture quality when using the Cat.5 extender will depend on the Cat.5/5e/6 cable 

quality and also on the signal quality generated by the graphics card used. To optimize the 

picture quality high quality amplifiers, equalizers and an auto skew compensation circuits are 

used in the Cat.5 Receiver unit to compensate for the attenuation and for the different lengths of 

the individual twisted pairs inside long Cat.5/5e/6 cables. 

 

In comparison to the IP Access Extender solution the Cat.5 Extender provides a real time 

analog KVM signal. And the Cat.5 KVM Extender does not require any software for operation as 

it just operates as an analog KVM signal extender. 

 

The Cat.5 KVM Extender module consists of two units: The local Cat.5 Extender Transmitter 

module fitted into the KVM Switch slot and the remote Cat.5 Extender Receiver unit installed at 

the remote user’s location.  

 

The remote Cat.5 Extender Receiver unit includes a local KVM switch which allows the remote 

user to also connect a local workstation to the receiver unit and switch between the local 

workstation and remote KVM Switch access.  

 

4.2. Cat.5 KVM Extender Installation 

 

Before you install the local Cat.5 Extender Transmitter module into the KVM switch ensure all 

connected computers are switched off and the power supply is unplugged. Proceed to unscrew 

and remove the small metal cover on rear of the KVM switch. Carefully slide the module into the 

slot and secure in place with the screw previously removed.  

 

Now install the remote Cat.5 Extender Receiver unit at the remote user’s location. You will need 

a VGA monitor and a USB mouse and keyboard to connect to the receiver unit. Connect your 

local workstation to the receiver unit if required using the dedicated KVM system cable included 

with the Cat.5 KVM Extender. Finally connect the Cat.5/5e/6 cable and the power supply unit. 

 

The KVM cable provided can be used to connect either PS/2 or USB equipped computers in the 

same way as previously described for connecting computers to the KVM switch in section 1.6. 

 

A dedicated Cat5/5e/6 cable with RJ-45 connectors is required to connect the Receiver unit and 

the Extender module located in the KVM switch. This connection must not be made via a “Live” 

Ethernet connection but only via multiple cable segments using patch cables, patch panels and 

wall sockets. Please consider the maximum resolution versus length limitations as mentioned 

previously. Please also try to limit the number of connections between the transmitter and 

receiver unit as this will help to reduce any signal loss introduced.   

 

You may now proceed to power up all connected equipment and check for correct operation.  

 

  

Section 4                                                                         CAT. 5 Extender Access & Operation

 

 

21 

 

4.3. Cat.5 KVM Extender Operation 

 

The Cat.5 Extender Receiver unit incorporates its own OSD menu which allows switching 

between the local workstation and remote KVM Switch as well as configuration of the unit.  

 

To invoke the hotkey and OSD operation of the Cat.5 Receiver unit simply press the hotkey 

(factory default setting is Caps Lock) twice and press any other command from the list below 

within 2 seconds: 

 

Command 

Action 

F1 

Selects the OSD Help Menu of the receiver unit 

F2 

Selects the OSD Hotkey setting menu of the receiver unit 

Toggle between local workstation and remote KVM switch access 

Turn ON / OFF the beep confirmation sound of the receiver unit  

Turn ON Autoscan functions of the receiver unit. Display will switch at 5 

second intervals between the local workstation and the KVM switch 

Press any key to stop scanning 

Auto adjusts the amplifiers and equalizers of the remote Cat.5 Extender 

receiver unit. This auto adjustment is also performed automatically each 

time the receiver unit is powered on  

 

To change the default hotkey simply activate the local OSD F2 menu. Choose a new hotkey by 

typing in the appropriate number key as listed in the local OSD F2 menu.  

 

The following hotkeys are available: Scroll Lock / Caps Lock / Left Ctrl / Right Ctrl / Left Alt / 

Right Alt / Left Win / Right Win. When choosing a new hotkey try to avoid using a hotkey 

already used by any connected KVM switches as conflicts may arise when switching ports. 

 

 

 

Содержание 32530

Страница 1: ...he required optional IP or Cat 5 access modules can be purchased separately and are simply installed into the back of a U8 16 Modular KVM Switch This manual also covers the KVM Switch U8 16 C another...

Страница 2: ...witch Operation 13 3 2 Keyboard Hotkey Selection 15 3 3 On Screen Display Menu OSD Port Selection 17 Section 4 19 4 1 Cat 5 KVM Extender Features 20 4 2 Cat 5 KVM Extender Installation 20 4 3 Cat 5 KV...

Страница 3: ...6 IP Local Console Remote Access Remote local control of multiple computers Section 1 Introducing the U8 16 IP 5 The U8 16 IP provides a non intrusive solution for remote access and control because th...

Страница 4: ...ically restored when switching between computers LED Display for easy status monitoring Buzzer sound for port switching confirmation Uses special single connector USB PS 2 VGA KVM cables with 15 Way H...

Страница 5: ...or the attached computer is not switched on Shift Button This button allows ports 9 to 16 to be selected Bank Select Button Pressing this button switches banks and allows the computers connected to sl...

Страница 6: ...to the console ports of the U8 16 MASTER KVM Switch Step 2 Connect the first Slave Use the daisy chain cable to connect the daisy chain port of the MASTER previous KVM Switch and the other end to the...

Страница 7: ...itch without having to power it off as long as it is currently not connected to the console In most cases the PS 2 mouse and keyboard signals will be maintained and will not be lost b The mouse driver...

Страница 8: ...the keyboard is in hotkey mode If you have not pressed any key in hotkey mode within 2 seconds the keyboard will return back to Operating System control status For the U series KVM switches it is pos...

Страница 9: ...your password a STATUS OSD display will be displayed System 02 102 Bank 1 Port 02 System PC name Scroll Lock recent hotkey 02 selected port Auto LOGOUT function During normal operation if no input fro...

Страница 10: ...users and their passwords For both up to 8 characters can be used Select 05 ACCESS LIST for Supervisor only to assign access restrictions to users for certain ports Default setting is no access restr...

Страница 11: ...ing the dedicated KVM system cable included with the Cat 5 KVM Extender Finally connect the Cat 5 5e 6 cable and the power supply unit The KVM cable provided can be used to connect either PS 2 or USB...

Страница 12: ...U processing time Transporting large amounts of data over TCP IP requires a high bandwidth connection Limited bandwidth may restrict or limit the possible screen resolutions and colour depths which ca...

Страница 13: ...Type config and press the Enter key Wait a few seconds for the configuration information to appear As you proceed the following questions will appear on the screen To accept the default values shown i...

Страница 14: ...o the keyboard settings Remote Mouse Settings A common problem with KVM devices is the synchronization between the local and remote mouse cursors The U8 16 IP addresses this problem with an intelligen...

Страница 15: ...Mode where only the remote mouse pointer is visible Activate this mode in the open Remote Console and click into the window area The local mouse pointer will be hidden and the remote one can be contro...

Страница 16: ...e host system using a securely encrypted connection you need a browser that supports the HTTPS protocol Strong security is only assured by using a key length of 128 Bit Some older browsers do not have...

Страница 17: ...that runs over this connection is neither HTTP nor HTTPS but RFB Remote Frame Buffer Protocol RFB needs to establish a connection to port number 443 Your local network environment has to allow this c...

Страница 18: ...menu A short description of the each of the options follows Monitor Only Toggles the Monitor only filter on or off If the filter is switched on no remote console interaction is possible but monitoring...

Страница 19: ...es Reset all settings to the factory made defaults Save Changes Save changes permanently Section 5 IP Access Configuration Operation 37 Undo Changes Restore last settings Soft Keyboard Opens up the su...

Страница 20: ...oding is enabled a value in brackets displays the compressed transfer rate For more information about Monitor Only and Exclusive Access settings see the relevant sections on page 35 Section 5 IP Acces...

Страница 21: ...t interface is entirely controlled with the appropriate functions of the web interface Once you have successfully logged into the U8 16 IP a command line will be presented and you can enter management...

Страница 22: ...output in the specified output file tmp floppy image Adjust both parameters exactly to your needs input device etc Section 5 IP Access Configuration Operation 43 Windows Windows users should use the t...

Страница 23: ...our hard disk For example with Nero choose Copy and Backup Then navigate to the Copy Disc section Select the CD ROM or DVD drive you would like to create an image from Specify the filename of the imag...

Страница 24: ...SAMBA SAMBA must be set up properly You may either edit the SAMBA configuration file etc samba smb conf or use the Samba Web Administration Tool SWAT or WebMin to set the correct parameters Section 5...

Страница 25: ...tion 49 1 Choose the drive you wish to redirect from the drop down list Enter your user name and password and click OK 2 Access the host computer from the Remote Console window You will see that the r...

Страница 26: ...r account has only the permission to open and use the Remote Console The default password for both accounts is pass Ensure you change the passwords as soon as you have installed and accessed the U8 16...

Страница 27: ...timized adjustment of compression and colour depth for the indicated network speed Section 5 IP Access Configuration Operation 53 Manually Allows adjustment of both compression rate and colour depth i...

Страница 28: ...ly catching this keystroke already Typical examples are Control Alt Delete in Windows and DOS which is always caught or Control Backspace on Linux for terminating the X Server The syntax to define a n...

Страница 29: ...nput signal A large filter setting needs less network traffic and leads to a faster video display but small changes in some display regions may not be recognized immediately A small filter displays al...

Страница 30: ...ion The maximum network traffic generated through the U8 16 IP s Ethernet device Value in Kbit s Enable Telnet access Set this option to allow access to ARA express using the Telnet Gateway see the Se...

Страница 31: ...rver Check time The U8 16 IP registers itself in the Dynamic DNS server at this time Check interval This is the interval for reporting again to the Dynamic DNS server by the U8 16 IP Section 5 IP Acce...

Страница 32: ...n machine with the Download CSR button see the illustration on the next page 2 Send the saved CSR to a CA for certification You will get the new certificate from the CA after a more or less complicate...

Страница 33: ...needs to be connected to the serial interface of the U8 16 IP Connecting to the U8 16 IP using a telephone line allows you to set up a dedicated point to point connection from your console computer to...

Страница 34: ...virtually every IP address is possible but you must make sure it is not interfering with the IP settings of the U8 16 IP switch and your console computer The default value will work in most cases Pas...

Страница 35: ...and is available after the U8 16 IP has been started If the U8 16 IP loses power or a hard reset is performed all logging data will be lost To avoid this use one of the log methods described below Se...

Страница 36: ...ser s its IP address from which host the user comes from and its activity status is displayed RC means that the Remote Console is open If the Remote Console is opened in exclusive mode the term exclus...

Страница 37: ...the appearance of the web interface is correct To do this in Internet Explorer select Tools Internet Options General Delete Files Tick the check box Delete all offline content and click OK Tip Should...

Страница 38: ...guarantee that the U8 16 IP will work with all known mice especially those developed and produced after the U8 16 IP s introduction Avoid moving the mouse or pressing the mouse buttons when switching...

Страница 39: ...F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 PRINTSCREEN SCROLL LOCK BREAK INSERT HOME PAGE UP DELETE END PAGE DOWN UP LEFT DOWN RIGHT NUM LOCK NUMPAD0 NUMPAD1 NUMPAD2 NUMPAD3 NUMPAD4 NUMPAD5 NUMPAD6 NUMPAD...

Страница 40: ...pour le recyclage de tout quipement lectrique et lectronique Chaque Etat membre de l Union Europ enne a mis en application la nouvelle r glementation WEEE de mani res l g rement diff rentes Veuillez...

Отзывы: