IP58, IQ58, IQ36
WARNING
Please check the position of the 0 pulse and set it if necessary whenever you set
a new resolution next to the
parameter or reverse the counting
direction.
NOTE
The width of the 0 pulse can be set next to the
options are available:
90° el (gated A, B)
and
180° el (gated A)
. Please note
that the 0 pulse having a width of 90 electrical degrees is synchronised with A
and B pulses, while the 0 pulse having a width of 180 electrical degrees is
synchronised with A pulse. For further information please refer to page 35.
NOTE
It is possible to set the 0 pulse position also by either sending a signal via PLC or
other controller through the dedicated input -see the “4.8 Index pulse setting
input (IP-, CKP- models only)” section on page 21-; or by pressing the external
button located in the rear side of the encoder enclosure -see the “4.11 Index
pulse setting external button (Figure 1) (IP-, CKP- models only)” section on page
23. Both these options are only available on IP-, CKP- models.
Output circuit
NOTE
This parameter is only available on IP-, CKP- models, it is not displayed if you
connect with IQ-, CKQ- models.
This parameter allows to set the voltage level of AB0, /AB0 output channels. You
can choose between 5V and the encoder power supply voltage level (+Vdc). In
the drop-down box select the
5V (line driver/TTL)
option to have a voltage
level of 5V at output channels; select the
5-30V (PP/LD universal)
option to
have a voltage level at output channels according to the encoder power supply
voltage level (5V to 30V).
Default = 5-30V (PP/LD universal)
Min. value = 5V (Line driver/TTL); max. value = 5-30V (PP/LD universal)
EXAMPLE
Let's assume that the encoder power supply voltage level is 12V; in this case you
can have the output channels at either 5V voltage level -by setting the
5V (Line
driver/TTL)
option- or 12V -by setting the
5-30V (PP/LD universal)
option-.
MAN IP58_IQ58_IQ36 E 1.6
Programming interface
36 / 44
Содержание CKP58
Страница 4: ...Max rpm 37 Encoder status 38 5 5 Diagnostics page 39 6 Default parameters list 40 ...
Страница 41: ...This page intentionally left blank ...
Страница 42: ...This page intentionally left blank ...
Страница 43: ...This page intentionally left blank ...