IP58, IQ58, IQ36
4.5 Connection of the shield
For signals transmission always use shielded cables. The cable shielding must be
connected properly to the metal ring nut
3
of the connector in order to ensure
a good earthing through the frame of the device. To do this disentangle and
shorten the shielding
1
and then bend it over the part
2
; finally place the ring
nut
3
of the connector. Be sure that the shielding
1
is in tight contact with the
ring nut
3
.
4.6 Ground connection
Minimize noise by connecting the shield and/or the connector housing and/or
the frame to ground. Make sure that ground is not affected by noise. The
connection point to ground can be situated both on the device side and on
user’s side. The best solution to minimize the interference must be carried out by
the user. You are advised to provide the ground connection as close as possible
to the encoder.
4.7 AB0, /AB0 output channels