IP58, IQ58, IQ36
4 Electrical connection
WARNING
Electrical connection has to be carried out by qualified personnel only, with
power supply disconnected and mechanical parts compulsorily in stop.
WARNING
If wires of unused signals come in contact, irreparable damage could be caused
to the device. Thus they must be cut at different lengths and insulated
singularly.
4.1 Cable and connectors conne I
2
C serial interface
Function
T12 cable
M23 12-pin
1
M12 12-pin
A
Violet
1
3
/A
Yellow
2
4
B
Grey
3
5
/B
Pink
4
6
0
Green
5
9
/0
Brown
6
10
+5Vdc +30Vdc
Brown_Green
7
2
0Vdc
White_Green
8
1
Index pulse setting
2
White
9
7
Counting direction
2
Blue
10
8
SDA
Red
11
11
SCL
2
Black
12
12
Shield
Shield
Case
Case
1 Only available on IP58 and IQ58 series
2 Only available on IP- and CKP- models
4.2 T12 cable specifications
Model
: LIKA T12 cable
Cross section
: 4 x 0.25 mm
2
+ 4 x 2 x 0.14 mm
2
twisted pairs (24/26 AWG)
Jacket
: TPU, extra flexible
Shield
: tinned copper braid, coverage > 85%
Outer diameter : 6.1 mm ±0.1 mm (0.24” ±0.004”)
Min. bending radius
: fix min. 25 mm (0.98”) / dynamic min. 45 mm (1.77”)
Work temperature : fix -40 +90°C (-40° +194°F) / dyn -50 +90°C (-58° +194°F)
Conductor resistance : < 90
/km (0.25 mm
2
), < 148
/km (0.14 mm
2
)
MAN IP58_IQ58_IQ36 E 1.6
Electrical connection