4.8 Index pulse setting input (IP-, CKP- models only)
NOTE
The Index pulse setting input is only available on IP-, CKP- models.
This encoder provides the zero signal (Index pulse) once per revolution as
relative positioning reference (home position, see the Figure here above). In this
way a unique position can be identified at a well-known point in the 360°
revolution of the encoder shaft. This input allows to set the point in the
revolution at which the 0 pulse will be output. This function is useful, for
example, when you want the zero position of the encoder and the zero
mechanical position of the axis to match. When you want to set the position of
the 0 signal in the revolution you must send a command via PLC or other
controller to the encoder through the dedicated input. Connect the Index pulse
setting input to 0Vdc if not used. To set the zero position, connect the Index
pulse setting input to +Vdc for 100 µs at least, then discVdc. Normally
voltage must be at 0Vdc. We suggest moving the axis to the desired position,
then activate the Index pulse setting function while the encoder and the
mechanical assembly are in stop.
WARNING
Please check the position of the 0 pulse and set it if necessary whenever you set
a new resolution next to the
parameter or reverse the counting
direction.
NOTE
The width of the 0 pulse can be set next to the
options are available:
90° el (gated A, B)
and
180° el (gated A)
. Please note
that the 0 pulse having a width of 90 electrical degrees is synchronised with A
and B pulses, while the 0 pulse having a width of 180 electrical degrees is
synchronised with A pulse. For further information please refer to page 35.
NOTE
It is possible to set the 0 pulse position also by either pressing the external
button located in the rear side of the encoder enclosure -see the “4.11 Index
pulse setting external button (Figure 1) (IP-, CKP- models only)” section on page
23 - this option is only available on IP-, CKP- models; or by means of the
programming interface -see the
parameter on page 35 - this
option is available on both IP- and IQ- series.
MAN IP58_IQ58_IQ36 E 1.6
Electrical connection
21 / 44
Содержание CKP58
Страница 4: ...Max rpm 37 Encoder status 38 5 5 Diagnostics page 39 6 Default parameters list 40 ...
Страница 41: ...This page intentionally left blank ...
Страница 42: ...This page intentionally left blank ...
Страница 43: ...This page intentionally left blank ...