IP58, IQ58, IQ36
the encoder enclosure allows to set the point in the revolution at which the 0
pulse will be output. This function is useful, for example, when you want the
zero position of the encoder and the zero mechanical position of the axis to
match. When you want to set the position of the 0 signal in the revolution you
must move the axis to the desired position, then press the Index pulse setting
button while the encoder and the mechanical assembly are in stop.
Figure 1 - Diagnostic LEDs and Index pulse setting button
WARNING
Please do not press the Index pulse setting external button when the encoder
configuration interface program is running.
WARNING
Please check the position of the 0 pulse and set it if necessary whenever you set
a new resolution next to the
parameter or reverse the counting
direction.
NOTE
The width of the 0 pulse can be set next to the
options are available:
90° el (gated A, B)
and
180° el (gated A)
. Please note
that the 0 pulse having a width of 90 electrical degrees is synchronised with A
and B pulses, while the 0 pulse having a width of 180 electrical degrees is
synchronised with A pulse. For further information please refer to page 35.
MAN IP58_IQ58_IQ36 E 1.6
Electrical connection
24 / 44