5. Software Control - Lightware Device Controller
UMX-HDMI-140 series– User's Manual
51
Applied firmware package: v1.3.0b5 | LDC software: v2.5.6b2
SalvoHttp Status Page (Receiving HTTP Message)
DIFFERENCE:
This feature is available only in UMX-HDMI-140-Plus model from FW package v1.3.0b5.
ATTENTION!
This feature means sending
HTTP
messages from an external device to the Lightware device.
Encrypted transmission (
HTTPS
) is not supported.
In this case, a batch of commands can be sent over HTTP to the Lightware device for processing. Post the
commands to the <IP_address>/protocol.lw3 address and the commands are processed immediately and
sequentially.
#http #new
Control commands can be sent to the Lightware device, but it is not suitable for querying a parameter/status
since the LW3 responses are not sent back to the sender.
ATTENTION!
If the
Cleartext Login (Login Settings)
is enabled in the device, the login has to be the first
command. No commands will be processed without a successful login. See the syntax in the
SalvoHttp tab in the Control/Ethernet menu