5. Software Control - Lightware Device Controller
UMX-HDMI-140 series– User's Manual
62
Applied firmware package: v1.3.0b5 | LDC software: v2.5.6b2
MAC Filter Allowlist
DIFFERENCE:
This feature is available only in UMX-HDMI-140-Plus model from FW package v1.3.0b5.
Another level of the security is the MAC Filtering tool. You can create a list of network devices based on the
MAC address which are allowed:
#macfilter
#new
▪
Controlling the device (Send option), or
▪
Querying parameters (Receive option) to/from the Lightware device.
Do not forget to press the
Apply changes
button to store the new settings.
ATTENTION!
The first three lines are factory default values and they are necessary for the proper working.
ATTENTION!
If the device is installed in a network where it gets IP address from a DHCP server and you
plan to use the MAC filtering, make sure the MAC address of the DHCP server is added to the white list.
Otherwise, the device will not get IP address and will be unreachable.
5.11.3. Front Panel
Front panel tab in the Settings menu
Front panel operation LEDs and buttons can be configure in this tab.
▪
You can disable the functionality of the front panel buttons with marking the
Lock front panel
option.
This is same method of the control lock made by the front panel buttons. See the details in the
#controllock #buttonlock #lockbutton
▪
Dark mode
enable/disable: video and audio LEDs on the front panel are turned off 60 seconds after
enabling the dark mode.
#darkmode
▪
Enable default function for Video Select / Audio Select / Function (Show me) button
: when this property is
disabled, it means that pushing the button will not perform the original function. This makes the
button free for programming custom function by the
. This setting is also available via
LW3 protocol, for more details see the
Disable the Default Function of the Front Panel Buttons
section.
5.11.4.
Backup
Details about this function can be found in the
Backup (Configuration Cloning)
section.
5.11.5.
System
System tab in Settings menu
Cleartext Login (Login Settings)
DIFFERENCE:
This feature is available only in UMX-HDMI-140-Plus model from FW package v1.3.0b5.
This cleartext login tool allows setting a password for login, thus, the device will not accept any command
coming from a control interface (RS-232, Ethernet, etc…) without login. The device will be visible in the Device
Discovery window (as the device type and the serial number can be queried without login) but connection
can be established only after successful login. The login is valid until a TCP socket break in case of Ethernet
connection.
#login #new
ATTENTION!
If the login is enabled, the password will be asked when opening
INFO:
The login password is erased and the login is disabled when restoring the factory default values.
Further functions
▪
Download system log
- saving the file of the device.
▪
Load factory defaults
- recalling factory defaults settings and values. All factory default settings are
listed in the
section.
▪
Reboot
- rebooting the system.
#factory
#log
#systemlog
#reboot #restart