7. LW3 Programmers’ Reference
UCX series – User's Manual
114
Applied firmware package: v1.2.0b9 | LDC software: v2.5.10b1
8.6.16.
OutputSignalType
Command and Response
#signaltype
ç
SET·/V1/MEDIA/VIDEO/
<out>
.OutputSignalType=
<signal_type>
æ
pw
·
/V1/MEDIA/VIDEO/
<out>
.OutputSignalType=
<signal_type>
Parameters
Parameter
Parameter description
Values
Value description
<signal_type>
Signal type setting
Auto
The outgoing signal type is HDMI.
DVI
The outgoing signal type is DVI.
Example
ç
SET /V1/MEDIA/VIDEO/O1.OutputSignalType=Auto
æ
pw /V1/MEDIA/VIDEO/O1.OutputSignalType=Auto
8.6.17.
Output5VMode
The 5V power towards the sink can be enabled or disabled as follows:
Command and Response
ç
SET·/V1/MEDIA/VIDEO/
<out>
.Output5VMode=
<5V_pwr>
æ
pw·/V1/MEDIA/VIDEO/
<out>
.Output5VMode=
<5V_pwr>
Parameters
Parameter
Parameter description
Value
Value description
<5V_pwr>
5V power towards the sink
On
Off
Enable 5V power on HDMI port
Disable 5V power on HDMI port
Example
ç
SET /V1/MEDIA/VIDEO/O1.Output5VMode=On
æ
pw /V1/MEDIA/VIDEO/O1.Output5VMode=On
8.7.
Welcome Screen Settings
8.7.1.
Display Welcome Screen Image
Command and Response
#welcomescreen
ç
SET
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.ImageEnabled=
<image_state>
æ
pw
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.ImageEnabled=
<image_state
Parameters
Parameter
Parameter description
Values
Value description
<image_state>
true
false
The welcome screen image is displayed.
The welcome screen image is not displayed.
Example
ç
SET /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.ImageEnabled=true
æ
pw /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.ImageEnabled=true
8.7.2.
Display Welcome Screen Text
Command and Response
ç
SET
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageEnabled=
<text_state>
æ
pw
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageEnabled=
<text_state
Parameters
Parameter
Parameter description
Values
Value description
<text_state>
true
false
The welcome screen text is displayed.
The welcome screen text is not displayed.
Example
ç
SET /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageEnabled=false
æ
pw /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageEnabled=false
8.7.3.
Set Welcome Screen Text
Command and Response
ç
SET
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageText=
<text>
æ
pw
·/V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageText=
<text>
Parameters
The
<text>
may consist of letters (A-Z) and (a-z), hyphen (-), underscore (_), numbers (0-9), space ( ) and dot
(.). Max length: 63 character. Longer names are truncated.
Example
ç
SET /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageText=info
æ
pw /V1/MEDIA/VIDEO/I5/WELCOMESCREEN.MessageText=info