53
- “T1-WorkTension1”;7
- “T2-WorkTension2”;
- “TE-TensionError”;
- “TA-Time Alarm”;
- “TR-TensionRelax”;
- “SR-Speed Relax”;
- “AO-Adv.Options”;
- “YR-Yarn Rigid.”;
- “BR-Brake Rate”.
In cases when the “Serial Communication Control” feature is enabled, the
related blocked parameter icon will be displayed on entering the blocked
parameter editing page:
Note: the SPIN parameters can also be managed via the POCKET
(A7N2S750) terminal unit and cable (A3N1SA1204), or via the KYC
(Connect) device.
The list of parameters that can be found on the Pocket/KYC is similar to that
on the SPIN display, except for:
1. Parameter “LC-Lenght count”. The Pocket/KYC features 2 parameters to
set the reference value: “LC-LnCn m” (reference value in metres) and
“LC-LnCn Km” (reference value in Kms). If the spool is 36,300 metre long,
you set “LC-LnCn Km” = 36 and “LC-LnCn m” = 300. Moreover there are
2 parameters for the real-time measurement of the consumed yarn: “LC-
Meas. m” and “LC-Meas. Km” to measure the metres and the Kms coun
ted by the counter unit.
2. Parameter “TD-Des. Dgr”: active tension. Via the Pocket device the ope
rator can change the tension on the SPIN by acting on this parameter. If
T1 is active on the SPIN, by changing “TD-Des. Dgr” T1 changed, too. If
T2 is active, by changing “TD-Des. Dgr”, T2 also changes.
3. Parameter “SC-SerCont”: this parameter allows the feeder to be control
led from display unit and from Pocket/KYC device or, alternatively, from
Pocket/KYC device only.
“SC-SerCont” = 0 Pocket/KYC device and Display Control
“SC-SerCont” = 2 Control only from Pocket/KYC device. The SPIN display
is locked.
4 - SETTING THE OPERATING PARAMETERS
Содержание SPIN1
Страница 2: ......
Страница 6: ......
Страница 13: ...13 1 GENERAL FEATURES 1 5 OVERALL DIMENSIONS 40 140 60 65 50 77 5 73 5 50 Weight 350 g...