SWITCH 5: LED BLINKING RESET
(Led Blinking due to "TE-Tension Error" alarm)
0 = T2
➝
T1
1 = T1
➝
T2
It defines the reset mode of the “TE-Tension Error” alarm display (blinking
Leds) related to the INC/DEC signals.
N.b.:
− Please bear in mind that the T1 position as to the INC/DEC signals
depends on how the “AO-0 - INC/DEC SIGNAL POLARITY” option
is set.
− Remember that the reset is controlled by the INC/DEC signal
changeover. Hence it will be performed in any case, even if the T2
parameter is set to OFF.
Examples:
LED BLINKING RESET (Led blinking due to a "TE" alarm) = 0
If the device is in T1 and goes into alarm, the alarm condition display will only
be reset by switching the device to T2 and then back to T1 through the
INC/DEC signals.
LED BLINKING RESET (Led blinking due to a "TE" alarm) = 1
If the device is in T1 and goes into alarm, the alarm condition display will only
be reset by switching the device to T2 through the INC/DEC signals.
N.B.: please read the indications provided below for switch 6.
AO-5
- LED BLINKING RESET
(Led blinking due to a "TE" alarm) = 0
T2
➝
T1
Changeover from T2 to T1.
AO-5
- LED BLINKING RESET
(Led blinking due to a "TE" alarm) = 1
T1
➝
T2
Changeover from T1 to T2.
4 - SETTING THE OPERATING PARAMETERS