3-15 Energizing the Installed AC Module System
A. Make sure that the branch circuit breaker is initially turned off.
B. Check whether all of AC cable connectors are properly engaged. Refer to
3-8 Coupling AC cable
connectors and 3-9 Building an array of AC modules.
C. Confirm that the last AC module’s cable connector is appropriately sealed with an end cap.
D. Ensure grounding wire connects all of AC module running to grounded distribution panel. Refer
to
3-11 Grounding.
E. Engage the AC cable connector of the last AC module with connector of the transition cable
which should be manually made from an extension cable.
F. Turn on the circuit breaker. After approximately 6 min., the AC module system will begin
producing power if sunlight is sufficient.
•
Plan the installation work in moderate weather. There is a risk of electric shock when it is raining or snowing.
•
To prevent the risk of accidents, use proper PPE (Personal Protective Equipment) including helmets, eye
protection and gloves at all times.
•
If installation location is high above ground, make sure to use Fall Protection System during the installation.
•
For safety, only qualified personnel should perform the services.
B
B
C
E
Meter
2-pole
N L1 L2
20A
G
D
Distribution panel
AC junction box
An array of AC modules
A,F