Electronics
AC Module System Installation Manual
Copyright © 2020 LG Electronics.
All Rights Reserved.
29
Rev. 1.0
Requirement for the landscape formation.
Unlike a connection in a portrait orientation, two AC modules in a landscape orientaion must be placed with a gap of at
least 6mm (0.24 inch) and no more than 50mm (1.95 inch). Otherwise, the length of the AC cables is not enough for
male and female connectors to be fully connected.
Use proper transition cable for connecting the array with AC junction box. (Refer to
3-12 Connecting Array of AC
Modules-to-Distribution Panel
guiding installers to make a transition cable from an extension cable) Seal the AC cable
male or female connector of the last AC module using an appropriate end cap. End caps can be found in an extension cable.
If AC junction box is on the right side of a 3-by-4 PV array in landscape orientation,
<50mm
<1.95 inch
<50mm
<1.95 inch
If AC junction box is on the left of a 3-by-4 PV array in landscape orientation,
Possible combination of AC modules for array design
Male connector
Female connector